Seeker D User’s Guide
Document Num., Rev. 4
May 2018
Page 50
Selecting a Distance Correction Preset
The Distance Correction display is used to select the distance correction preset used by
the Seeker D. The preset distances are numbered from 1 to 8 and can be configured using
the Seeker Setup software. The Seeker D is programmed at the factory with the following
preset distances:
DIST #
Enabled
Distance
Units
1
YES
6
Meters
2
NO
12
3
NO
24
4
NO
48
5
NO
72
6
NO
96
7
NO
120
8
NO
148
To select a preset frequency, turn your Seeker D on and press the
DISTANCE
button.
• When the
DISTANCE
button is selected, the distance preset will step through the
enabled presets in numerical order starting at 1 and ending at 8 as indicated by the
red circle in the following images.
• The distance value that corresponds to the selected distance correction preset will
be displayed numerically as shown in the following images.
Preset #1
Preset #2
For detailed instructions on how to set the distance correction
values, see the Seeker Setup Software Operation Manual.