RF transmitter T16
Terminal
Description
If the zone is violated when the alarm system is armed, counting of entry time begins. If the
alarm system is not disarmed during this time,
an output OUT1 signal will be formed and a
message will be sent.
IN2 (IN3,
IN4, IN5,
IN6)
2 (3, 4, 5, 6) input terminal, selectable type: NC, NO, EOL (2,2 kΩ). (default setting NO).
Instant zone. If the zone is violated when the alarm system is armed,
an output OUT1 signal
will be formed and a message will be sent immediately.
OUT1
Output terminal, open collector type, current up to 1 A. For connecting a siren.
Blinking LED indicators on the
TM17
inform about activated inputs during the time the system is armed.
When the alarm is disarmed (by holding a key to the reader), the indicators do not stop blinking. To stop
the indicators from blinking, hold the key to the reader again.
LED indication of operation of the
TM17
reader.
Indicator
State
Description
1 (2, 3, 4, 5, 6)
Off
Zone not triggered
Red solid
Zone triggered
Red blinking
Triggered zone caused security system to trigger
State
Green solid
Security alarm area is disarmed
Green blinking
Exit time is being counted down
Red solid
Security alarm area is armed
Red blinking
Entry time is being counted down
Trouble
Off
No operational problems
9 red blinks
Problem with the connection to RS485 module
3.5
“Options” window