RF transmitter T16
After the
Read [F4]
button is clicked, the program will read and show settings currently saved on the
T16
.
With
TrikdisConfig
, set the required parameters using the following program window descriptions.
3.2
“Main” window
Settings group “Main settings”
Administrator access code
– grants full access to the transmitter’s configuration. The code can be up
to 6 symbols long and is made up of numbers or Latin characters. (Default code - 1234).
Installer access code
– grants limited access to the transmitter’s configuration (factory code
- 1234).
Security panel model
– specify the type of the security control panel that the transmitter will be
connected to.
Settings group “Radio frequency 1”
Enabled
– tick the box to turn on the transmitter’s radio channel.
RF protocol
– specify the radio protocol that will be used (RAS-2M, RAS-3, LARS, LARS1, LARS_RAS2M,
LARS1_RAS2M).
Account ID
– enter the user’s identification number for the internal and panel events sent by the
transmitter.
Group
– enter the partial user identification ID (used only with the LARS RF protocol).
Use security panel account
– tick the box and the control panel’s events will be sent with the security
control panel’s ID. Not all panels allow to use the identification number.
System
– radio network system number. Used for assigning objects (users) to groups in a radio
network.
RF name/frequency
– the name of the radio channel frequency, can be described in the window
Options > Available radio frequencies
.
RF power
– choose transmitter power (1-5 W).
Event transmit
– enter how many times to repeat event transmissions (1-10 times). (Recommended
to leave default settings).