Command 

Data 

Description 

PSW 

New 
password
 

Change password. E.g.:PSW 123456 654123 

TXTA 

Object name 

Set object name. E.g.:TXTA 123456 House 

TXTE 

N1=<TEXT> 

……

 

N5=<TEXT> 

Set SMS text about input or output activation. 

N1…N5

 – number of the terminal contact.  

E.g.: TXTE 123456 N1=Alarm in the living room 

TXTR 

N1=<TEXT> 

……

 

N5=<TEXT> 

Set SMS text about input or output  recovery. 

N1…N5

 - number of the terminal contact.  

E.g.: TXTR 123456 N5=Relay is off  

SETA 

NoX=phoneN
o#name
 

Add an administrator to the list. User‘s phone 
number  and  name  will  be  written  to  the 
specified  line.  Phone  number  has  to  be 
separated from the name using a hashtag (#). 
The  number  must  start  with  (+)  and  country 
code.  
E.g.: SETA 123456 No3=+37061234567#John 

NoX=DEL 

Delete  administrator’s  phone  number  and 
name from the specified place.  
E.g.: SETA 123456 No1=DEL 

SETU 

PhoneNo# 
name
 

Add  a  new  user.  Saves  user’s  phone  number 
and  username.  Phone  number  has  to  be 
separated  from  the  name  using  a  hashtag 
(#).The number must start with (+) and country 
code.  
E.g.: SETU 37061234567#John Snow 

DELU 

PhoneNo  

Delete a user using his phone number. E.g.: 

DELU 37061234567 

Name 

Delete a user using his name.  
E.g.: DELU 123456 John Snow 

SETD 

IDx=yy 

Set  „x“  input  inactivity  time.  „yy“  is  the 
inactivity  time  in  minutes,  from  0  to  2880. 
After the input is activated, controller will send 
a  notification  and  will  not  react  to  following 
circuit  disruptions  during  the  set  time.  If  0  is 
entered, inactivity will be turned off.  
E.g.: SETD 123456 ID1=30 

RESD 

IDx 

Resets  „x“  input  inactivity  time,  if  the 
countdown has started.  
E.g.: RESD 123456 ID1 

RESET 

 

Restart the controller.  
E.g.: RESET 123456 

TIME 

YYYY/MM/DD

HH:mm:ss 

Set time and date.  
E.g.: TIME 123456 2018/01/03,12:23:00 

RDR 

PhoneNo# 
SMStext 

Forward SMS messages to specified number. 
E.g.: RDR 37061234567#top-up the 
phone 10EUR
 

UUSD 

*UUSD code#  Sends  UUSD  code  to  the  network  operator. 

With UUSD codes (given by the operator) it is 
possible  to  check  and  top-up  the  SIM  card 
balance, execute other actions.  
E.g.: UUSD 123456 *245# 

Connect 

Protegus=ON 

Connect to Protegus cloud. E.g.: 

CONNECT 123456 PROTEGUS=ON 

Protegus=OFF  Disconnect from Protegus cloud.  

E.g.: CONNECT 123456 PROTEGUS=OFF 

Содержание GV17

Страница 1: ...a mobile phone Alternatively you can enter the SIM card PIN via TrikdisConfig program using a USB This manual describes how to install GV17 without configuring it via USB If needed using TrikdisConfig program or Protegus application you can Add and delete users up to 990 and administrators up to 7 Check the events log Additionally using TrikdisConfig program you can Set a schedule when users can c...

Страница 2: ...l Usually these contacts are a certain input x IN and common terminal COM The automatic gate has a gate state output OUT that shows when the gates are closed and when they are open The gate s state output can be a voltage output or a relay output In the schematic relay K1 is connected to a voltage automated gate output There is voltage 230V between the voltage outputs OUT and N of the automated ga...

Страница 3: ...0 to 5 Sufficient is 3 DATA Green solid Sending message Yellow solid Unsent events are stored in buffer POWER Blinking green Power supply is sufficient Blinking yellow Low power supply voltage Blinking green and yellow Configuration mode TROUBLE Not solid and not blinking No trouble 1 blink No SIM card 2 blinks Incorrect SIM card PIN code 3 blinks Cannot connect to GSM network 4 blinks Cannot conn...

Страница 4: ...egus system window click the button Control Click the control button Shining light or opened gates show that GV17 controllable output is active Remote control via SMS Control the relay output 5 OUT with these SMS commands OUTPUT5 xxxxxx ON OUTPUT5 xxxxxx OFF OUTPUT5 xxxxxx PULSE 002 xxxxxx 6 digit administrator password ON Turn on the output OFF Turn off the output PULSE ttt Turn on the output for...

Страница 5: ...A xxxxxx NoX PHONENo NAME xxxxxx 6 digit administrator password NoX X administrator s number in the list PHONENo User s phone number NAME User s name or email address The list of SMS commands Command Data Description INFO Request information about the controller The response will include controller type IMEI number serial number and software version E g INFO 123456 OUTPUTx ON Turn on the output x ...

Страница 6: ...ountry code E g SETU 123456 37061234567 John Snow DELU PhoneNo Delete a user using his phone number E g DELU 123456 37061234567 Name Delete a user using his name E g DELU 123456 John Snow SETD IDx yy Set x input inactivity time yy is the inactivity time in minutes from 0 to 2880 After the input is activated controller will send a notification and will not react to following circuit disruptions dur...

Страница 7: ...nfig from www trikdis com Make sure that the controller is connected to the internet and the communication with Protegus is enabled see part III Remote control via Protegus application After opening the program enter the IMEI Unique ID number of the device to Unique ID field and click Configure Click Read F4 to read the parameters already set in the controller Set the needed settings and after the...

Отзывы: