background image

 

 

Remote control via phone call 

Make a call to the number of the inserted SIM card. 

Default  settings  allow  everyone  to  control,  who  call  the  telephone 
number of the SIM card inserted to GV17.  

A call will turn on the 5 OUT relay output for 3 (three) seconds. The 
phone call is free of charge as the controller automatically rejects it. 

 

 

 

Remote control via Protegus application 

 

1.

 

 Turn on the internet access for the controller 

To enable connection with Protegus, send an SMS in such format to 
the telephone number of SIM card inserted in the GV17

Connect xxxxxx protegus=on,apn=internet 

xxxxxx 

6-digit administrator password  
(default password – 123456) 

LED indication 

LED 

LED Status 

Description 

NETWORK  
 

Green solid 

Connected to GSM network 

Blinking yellow  

GSM  signal  strength  from  0  to  5. 
Sufficient is 3. 

DATA  
 

Green solid 

Sending message 

Yellow solid 

Unsent events are stored in buffer 

POWER  
 

Blinking green 

Power supply is sufficient  

Blinking yellow 

Low power supply voltage 

Blinking  green 
and yellow  

Configuration mode 

TROUBLE  
 

Not  solid  and 
not blinking 

No trouble 

1 blink 

No SIM card 

2 blinks 

Incorrect SIM card PIN code 

3 blinks 

Cannot connect to GSM network 

4 blinks 

Cannot  connect  to  Protegus  or  to 
primary IP receiver 

5 blinks 

Cannot connect to backup IP 
receiver 

6 blinks 

Internal GV17 clock is not set 

7 blinks 

Power supply is insufficient  

If the controller LED indication is completely off, check the power supply 
and connections. 

!! Internet connection is necessary for communication with Protegus

Make sure that internet access is enabled for the SIM inserted into GV17

The first user who calls the controller (or sends an SMS) will become the 
system  administrator  and  will  be  the  only  one  who  can  manage  and 
control the GV17 with SMS commands. 

Содержание GV17

Страница 1: ...a mobile phone Alternatively you can enter the SIM card PIN via TrikdisConfig program using a USB This manual describes how to install GV17 without configuring it via USB If needed using TrikdisConfig program or Protegus application you can Add and delete users up to 990 and administrators up to 7 Check the events log Additionally using TrikdisConfig program you can Set a schedule when users can c...

Страница 2: ...l Usually these contacts are a certain input x IN and common terminal COM The automatic gate has a gate state output OUT that shows when the gates are closed and when they are open The gate s state output can be a voltage output or a relay output In the schematic relay K1 is connected to a voltage automated gate output There is voltage 230V between the voltage outputs OUT and N of the automated ga...

Страница 3: ...0 to 5 Sufficient is 3 DATA Green solid Sending message Yellow solid Unsent events are stored in buffer POWER Blinking green Power supply is sufficient Blinking yellow Low power supply voltage Blinking green and yellow Configuration mode TROUBLE Not solid and not blinking No trouble 1 blink No SIM card 2 blinks Incorrect SIM card PIN code 3 blinks Cannot connect to GSM network 4 blinks Cannot conn...

Страница 4: ...egus system window click the button Control Click the control button Shining light or opened gates show that GV17 controllable output is active Remote control via SMS Control the relay output 5 OUT with these SMS commands OUTPUT5 xxxxxx ON OUTPUT5 xxxxxx OFF OUTPUT5 xxxxxx PULSE 002 xxxxxx 6 digit administrator password ON Turn on the output OFF Turn off the output PULSE ttt Turn on the output for...

Страница 5: ...A xxxxxx NoX PHONENo NAME xxxxxx 6 digit administrator password NoX X administrator s number in the list PHONENo User s phone number NAME User s name or email address The list of SMS commands Command Data Description INFO Request information about the controller The response will include controller type IMEI number serial number and software version E g INFO 123456 OUTPUTx ON Turn on the output x ...

Страница 6: ...ountry code E g SETU 123456 37061234567 John Snow DELU PhoneNo Delete a user using his phone number E g DELU 123456 37061234567 Name Delete a user using his name E g DELU 123456 John Snow SETD IDx yy Set x input inactivity time yy is the inactivity time in minutes from 0 to 2880 After the input is activated controller will send a notification and will not react to following circuit disruptions dur...

Страница 7: ...nfig from www trikdis com Make sure that the controller is connected to the internet and the communication with Protegus is enabled see part III Remote control via Protegus application After opening the program enter the IMEI Unique ID number of the device to Unique ID field and click Configure Click Read F4 to read the parameters already set in the controller Set the needed settings and after the...

Отзывы: