Trikdis GV17 Скачать руководство пользователя страница 5

 

System administration via SMS 

1.

 

Changing the administrator‘s password 

To  ensure  safety,  change  the  default  administrator  SMS  password. 
Send an SMS in this format: 

PSW 123456 xxxxxx 

123456 

Default administrator password 

xxxxxx 

The new 6-digit administrator password 

2.

 

Allow only authorized users to control the system 

You can limit the users who can control the system. Send an SMS from 
the administrator‘s phone with people‘s phone numbers and names: 

SETU PHONENo#NAME 

xxxxxx 

6-digit administrator password 

PHONENo 

User‘s phone number 

NAME 

User‘s name or email address 

 

 

 

 

3.

 

Give the system administrator‘s rights to another user 

The  administrator‘s  rights  can  be  given  to  other  users.  They  will 
receive system‘s notifications and will be able to add users. Send an 
SMS in this format:  

SETA xxxxxx NoX=+PHONENo#NAME 

xxxxxx 

6-digit administrator password 

NoX 

X – administrator‘s number in the list 

PHONENo 

User‘s phone number 

NAME 

User‘s name or email address 

 

The list of SMS commands 

Command 

Data 

Description 

INFO 

 

Request information about the controller. The 
response  will  include:  controller  type,  IMEI 
number,  serial  number  and software  version. 
E.g.: INFO 123456 

OUTPUTx 

ON 

Turn on the output. „x“ – output number.  
E.g.: OUTPUT5 123456 ON 

OFF 

Turn off the output. „x“ – output number.  
E.g.: OUTPUT5 123456 OFF 

PULSE=ttt 

Turn on the output for a period of time

„ttt“ 

is pulse duration in seconds

, from 1 

to 999. E.g.:OUTPUT5 123456  PULSE=002 

ASKI 

 

Input status inquiry. E.g.: ASKI 123456 

ASKO 

 

Output status inquiry. E.g.: ASKO 123456  

After adding the first user‘s phone number to GV17 phone number list, 
the controller will only respond to calls from the listed phone numbers. 
The controller will ignore other calls. 

If you type No1 in the SMS message, you will transfer your administrator‘s 
rights to another user. 

Содержание GV17

Страница 1: ...a mobile phone Alternatively you can enter the SIM card PIN via TrikdisConfig program using a USB This manual describes how to install GV17 without configuring it via USB If needed using TrikdisConfig program or Protegus application you can Add and delete users up to 990 and administrators up to 7 Check the events log Additionally using TrikdisConfig program you can Set a schedule when users can c...

Страница 2: ...l Usually these contacts are a certain input x IN and common terminal COM The automatic gate has a gate state output OUT that shows when the gates are closed and when they are open The gate s state output can be a voltage output or a relay output In the schematic relay K1 is connected to a voltage automated gate output There is voltage 230V between the voltage outputs OUT and N of the automated ga...

Страница 3: ...0 to 5 Sufficient is 3 DATA Green solid Sending message Yellow solid Unsent events are stored in buffer POWER Blinking green Power supply is sufficient Blinking yellow Low power supply voltage Blinking green and yellow Configuration mode TROUBLE Not solid and not blinking No trouble 1 blink No SIM card 2 blinks Incorrect SIM card PIN code 3 blinks Cannot connect to GSM network 4 blinks Cannot conn...

Страница 4: ...egus system window click the button Control Click the control button Shining light or opened gates show that GV17 controllable output is active Remote control via SMS Control the relay output 5 OUT with these SMS commands OUTPUT5 xxxxxx ON OUTPUT5 xxxxxx OFF OUTPUT5 xxxxxx PULSE 002 xxxxxx 6 digit administrator password ON Turn on the output OFF Turn off the output PULSE ttt Turn on the output for...

Страница 5: ...A xxxxxx NoX PHONENo NAME xxxxxx 6 digit administrator password NoX X administrator s number in the list PHONENo User s phone number NAME User s name or email address The list of SMS commands Command Data Description INFO Request information about the controller The response will include controller type IMEI number serial number and software version E g INFO 123456 OUTPUTx ON Turn on the output x ...

Страница 6: ...ountry code E g SETU 123456 37061234567 John Snow DELU PhoneNo Delete a user using his phone number E g DELU 123456 37061234567 Name Delete a user using his name E g DELU 123456 John Snow SETD IDx yy Set x input inactivity time yy is the inactivity time in minutes from 0 to 2880 After the input is activated controller will send a notification and will not react to following circuit disruptions dur...

Страница 7: ...nfig from www trikdis com Make sure that the controller is connected to the internet and the communication with Protegus is enabled see part III Remote control via Protegus application After opening the program enter the IMEI Unique ID number of the device to Unique ID field and click Configure Click Read F4 to read the parameters already set in the controller Set the needed settings and after the...

Отзывы: