Ethernet communicator E10Tv2
•
When Use DHCP checkbox is selected, module registration in the network will be done automatically.
o
If automatic registration is unsuccessful, enter Internal IP address, subnet Mask and Gateway address
manually. E10Tv2 supports DNS service;
Settings → Access
•
Administrator code - allows full access to the configuration.
•
Installer code - allows access to the configuration, limited by administrator. Administrator can allow
installer to change:
o
Account number;
o
Reporting;
o
Ethernet settings;
o
Event summary.
3.2
Reporting → Alarm Receiving Centre (ARC) reporting
Reporting → Primary and backup
To have connection with Primary and Backup channels mark checkboxes Enable.
Fill in fields for Remote Host, Remote Port.
Choose reporting protocol TCP or UDP.
Enable PING Time and set time between signals in seconds (required for communication control).
Enter Encryption key (six-symbol hexadecimal number).
Reporting → Settings
Choose TCP protocol (an encryption protocol for messages to be sent to the monitoring station).
Enter MCI slave address to communicate with connected event message generating device.
Note: if administrator code is set as default (123456), it is not required to enter it and the request window
will not appear.