Ethernet communicator E10Tv2
b.
Remotely: run the configuration software TrikdisConfig. In section Remote access, field Unique ID
enter MAC address of communicator (MAC address is provided on the product package). (Optional) in
the field System Name enter the desired name to the module.
Press Configure.
3)
Click Read [F4] to read the communicators parameters and enter the Administrator or Installer code in the
pop-up window. In order for the program to remember the code, check the box next to Remember
password.
4)
To open a configuration file, click Open [F8].
Setting operation parameters
3.1
System settings
Settings → General:
•
Write an appropriate Account number (4 symbols hexadecimal number).
•
Select Use security panel account ID checkbox if messages from the security control panel must contain
its identification number.
•
Test period: periodic test messages will be sent according to a time interval set in this section
Settings → Ethernet settings
•
Internal MAC is unique for each Ethernet communicator, and it is not changeable.
Note: When new firmware is released, TrikdisConfig will ask if firmware can be updated, click yes, and new
window will open.
In order to save the previously entered data, check Preserve settings box.
Press Update [F12] and new firmware will be written to the communicator.
Note: if administrator code is set as default (123456), it is not required to enter it and the request window
will not appear.