MOUNTING
MOUNTING
MOUNTING
MOUNTING
MOUNTING
Arrangements must be made for the installation of a
standard voice-grade telephone line (touch-tone or
rotary, telco or PBX Port), as close to the unit mounting
location as possible. The telephone company may
require the following information.
FCC Registration No..................1Z8898-62546-DI-T
Ringer Equivalence..............................................0.8B
Connector............................................Terminal Block
When selecting a mounting location, Trigon
recommends some shelter be provided from direct rain
and sunlight. An overhang is usually sufficient. If a
heater element is installed, be sure to use a bi-metal
thermal switch to prevent over-heating during the
summer months.
Pull the wiring through the access hole in the lower
portion of the back plate (Fig. 2). Bolt the plate to the
surface through the four .312" mounting holes provided.
At this time, the wiring should NOT be energized.
Note: If used in extreme weather, a bead of silicon
sealant should be run around the outside top two thirds
of the unit, after the front case is secured. (Fig. 2b).
WIRING
WIRING
WIRING
WIRING
WIRING
1. Use the wiring diagram on pg. 5 for wire connection
information.
2. Isolate the phoneline from 120 VAC power wires.
This will prevent 60 Hz hum from occurring on the
phoneline. Use 22 AWG wire on Telco line run
distances of up to 2400 feet. Consult the factory for
distances greater than 2400 feet.
3. If all wiring and grounding is completed, mount the
faceplate onto the backbox.
Figure 2b
Seal top 2/3 of case
to mounting surface.
Side View
.52"
3.62"
+
+
4.04"
11.80"
5.38"
2.80"
+
+
3.0"
.52"
1.5"
2.02"
1 Hole
.88" Dia.
4 Holes
.312" Dia.
Note: Mount backplate with .88" Dia.
wire entry hole toward the bottom.
Figure 2
Figure 2b