  If you are using this manual as a programming guide
after the initial installation, you may find the TABLE OF
CONTENTS useful in locating the particular
programming procedure you need.

This manual contains all the information required to
install and program the TRIGON MINIGUARD HF-2.
If you are using this manual to install this unit, it is very
important to read all the sections in order.

You should read these instructions before you begin
installation.  This will insure that everything is done
efficiently.

The TRIGON HF-2 is a multi-number auto dialer.
Upon pressing the button, the HF-2 dials a programmed
telephone number. If the number dialed is busy or does
not answer, the HF-2 will hang up and dial the next
programmed number, up to a maximum of 10. If the
last programmed number is busy or does not answer,
the HF-2 will rollover and start the dialing process again
with the first phone number.

The HF-2 comes standard with 2 output relays. These
relays can be programmed to operate in several different
ways. Relays can be set to pulse momentarily for
camera call-up, they can be set to stay latched on for
the duration of the call, or they can be set to operate for
a timed duration (for door strike operation, etc).

There are two Modes of Operation incorporated in the
HF-2:

1.

The Standard Mode provides timed closure

of the relays and is typically used for access
control.

2.

The Emergency Mode causes relay activation

at the moment the start button is pressed.  This
mode is best suited for safety use when camera
and lighting control is desired.

A Site I.D. code feature provides for unit identification.
The Site I.D. code is a programmable four digit code
that is transmitted by the HF-2 when it receives a
command from the called party.  This code, when
interpreted by a Trigon DTMF Decoder, will identify
the calling unit.

.

Figure 1

TRIGON

TRIGON ELECTRONICS
        ORANGE CA.

CALL

HF-2

12"

4.2"

2.0"

Telephone Line-
Voice Grade 24 to 48V
22 AWG; Shielded
or Twisted,2 Conductor

Camera, Door or Gate

Secondary

Relay

Serial Printer

(18 AWG; Shielded, 3 Conductor)

Postal

Lock

Box

Primary
Output
Relay

Main Entrance

Power Cabling -
Shielded or Twisted,
2 Conductor,
18AWG  up to  250'
16AWG  up to  500'

Alarm
Shunt
Relay

Содержание Miniguard HF-2 Series

Страница 1: ...CA 92880 951 371 1730 Facsimile 951 371 2592 October 28 2004 Miniguard HF 2 Series Handsfree Telephone Entry Autodialer INSTALLATION and OPERATIONAL INSTRUCTIONS Firmware revision 020700 Rev A HF2XTRA...

Страница 2: ...fying Autodialed Telephone Number 6 Setting the Site ID Number 7 Changing Program Access Number 7 Setting the Relay Duration Timer 7 Setting Incoming Ring Count 7 Setting Dial Mode 7 Setting Call Legn...

Страница 3: ...omes standard with 2 output relays These relays can be programmed to operate in several different ways Relays can be set to pulse momentarily for camera call up they can be set to stay latched on for...

Страница 4: ...ound wire should go to a grounding rod or grounded metal conduit 5 Trigon recommends that an EMI filter Cornell Dubilier Model APF 1021 or equivalent be mounted between the 12 VAC transformer output a...

Страница 5: ...cabling 250 to 500 ALARM SHUNT IN OUT DSR COM RS 232 CARD READER EARTH GROUND TELEPHONE LINE EARPHONE MOUTH SPEAKER HF 2 MICROPHONE HF 2 MICROPROCESSOR AUDIO SPEAKER VOLUME PRIMARY RELAY 12V AC DC NO...

Страница 6: ...am commands will result in two 2 tones high low signifying their completion and acceptance Standard Mode allows the relays to be activated for a specified time period such as for access control purpos...

Страница 7: ...ust be in Program Mode 2 Press 5 3 Enter the number of rings desired 1 to 9 or 4 Enter 0 if an audible ring is desired from the HF 2 whenever it is called You will hear two beeps indicating command ac...

Страница 8: ...keypad STANDARD MODE When a CALL button is pressed the HF 2 dials a pre programmed phone number and monitors the line for the following signals Busy Signal The HF 2 will hang up and redial the number...

Страница 9: ...UBLE SHOOTING GUIDE TROUBLE SHOOTING GUIDE TROUBLE SHOOTING GUIDE LOSES MEMORY 1 Electrical noise on power line Install EMI RFI filter 2 Excessive electrical noise from strike Use low current strike 3...

Страница 10: ...Program Code r Ring Count 1 2 9 The star key of the telephone The pound sign key of the telephone Tones returned by the unit SECURITY DEPT OPERATION When Security personnel receive a call from the un...

Страница 11: ...ellow Telco White Call Btn White Call Btn 1 2 3 4 5 6 7 8 9 10 11 12 13 Black Speaker Red Speaker 14 15 16 17 18 19 20 21 22 23 24 25 Violet Relay primary Violet Relay primary Orange Relay secodary Or...

Страница 12: ...Page 12 MINIGUARD HF 2...

Отзывы: