If you are using this manual as a programming guide
after the initial installation, you may find the TABLE OF
CONTENTS useful in locating the particular
programming procedure you need.
This manual contains all the information required to
install and program the TRIGON MINIGUARD HF-2.
If you are using this manual to install this unit, it is very
important to read all the sections in order.
You should read these instructions before you begin
installation. This will insure that everything is done
efficiently.
The TRIGON HF-2 is a multi-number auto dialer.
Upon pressing the button, the HF-2 dials a programmed
telephone number. If the number dialed is busy or does
not answer, the HF-2 will hang up and dial the next
programmed number, up to a maximum of 10. If the
last programmed number is busy or does not answer,
the HF-2 will rollover and start the dialing process again
with the first phone number.
The HF-2 comes standard with 2 output relays. These
relays can be programmed to operate in several different
ways. Relays can be set to pulse momentarily for
camera call-up, they can be set to stay latched on for
the duration of the call, or they can be set to operate for
a timed duration (for door strike operation, etc).
There are two Modes of Operation incorporated in the
HF-2:
1.
The Standard Mode provides timed closure
of the relays and is typically used for access
control.
2.
The Emergency Mode causes relay activation
at the moment the start button is pressed. This
mode is best suited for safety use when camera
and lighting control is desired.
A Site I.D. code feature provides for unit identification.
The Site I.D. code is a programmable four digit code
that is transmitted by the HF-2 when it receives a
command from the called party. This code, when
interpreted by a Trigon DTMF Decoder, will identify
the calling unit.
.
Figure 1
TRIGON
TRIGON ELECTRONICS
ORANGE CA.
CALL
HF-2
12"
4.2"
2.0"
Telephone Line-
Voice Grade 24 to 48V
22 AWG; Shielded
or Twisted,2 Conductor
Camera, Door or Gate
Secondary
Relay
Serial Printer
(18 AWG; Shielded, 3 Conductor)
Postal
Lock
Box
Primary
Output
Relay
Main Entrance
Power Cabling -
Shielded or Twisted,
2 Conductor,
18AWG up to 250'
16AWG up to 500'
Alarm
Shunt
Relay