avoid ground loops, do not ground the shield at both

ends.  Use 600V insulated wire for this installation.

7. Isolate the Telco phoneline from 12 VAC power

wires.  This will prevent 60 Hz hum from occurring
on the phoneline.  Use 22 AWG wire on Telco line
run distances of up to 2400 feet.  Consult the factory
for distances greater than 2400 feet.

8. Power Relays 1 and 2 are dry contact, Form C type,

rated for 5 AMPS @ 30 VDC/ 250VAC.

9. The Shunt relay is a low-power (4 watt) reed relay.

It can be used for temporary alarm switch bypass,
video camera activation, etc.  The Shunt relay
activates with the #1 or #2 power relay, and
deactivates thirty seconds after relay release.

10. Connect printer wiring to the RS-232 port (Printer

IN to RS-232 OUT, Printer BUSY to RS-232 DSR,
Printer COM to RS-232 COM).

11. If all wiring and grounding is completed, mount the

faceplate onto the backbox.

1. Use the wiring diagram (Fig. 3) for wire connection

information.

2. Do not power any other device from the Trigon’s

12 VAC transformer.  If a substitute transformer is
used, be sure it is rated 12 VAC, 40VA, UL Class 2
listed.  The 12 VAC input power wires should be
18AWG, 600V, insulated wire.  This should be
sufficient for distances up to 200 feet.

3. Do not energize wires until installation is completed.

4. Ground the unit by attaching a separate 12 AWG

ground wire to the ground location on the terminal
block.  This ground wire should go to a grounding
rod or grounded metal conduit.

5. Trigon recommends that an EMI filter (Cornell-

Dubilier Model APF 1021 or equivalent) be mounted
between the 12 VAC transformer output and the unit.
EMI/RFI filters are available from Trigon.  Mount
the filter as close to the unit as possible.  Ground the
filter to the same point as unit ground.

6. Shielded cable is recommended.  Ground the

shielding to the same point as the unit and filter.  To

Arrangements must be made with the local telephone
company for installation of a standard voice-grade
telephone line (touch-tone or rotary) as close to the unit
mounting location as possible.  The telephone company
may require the following information.

FCC Registration No..................1Z8898-62546-DI-T

Ringer Equivalence..............................................0.8B

Connector............................................Terminal Block

The unit is designed to be as weather resistant as
possible*.  We do however recommend some shelter
from direct rain and sunlight. An overhang is usually
sufficient. Bolt the back plate (Fig. 2) to the mounting
surface using the four .312" holes in the chassis.  Feed
the wiring through the access hole in the rear of the
back plate.  At this point, the wiring should NOT be
live (energized).

Note:  If used in extreme weather, a bead of silicon
sealant should be run around the outside top two thirds
of the unit, after the front case is secured.

 (Fig. 2b).

* We sell optional Lighted Hood that helps with weather
protection

.52"

3.62"

+

+

11.80"

5.38"

2.80"

+

+

3.0"

.52"

1.5"

2.02"

1 Hole
.88" Dia.

4 Holes
.312" Dia.

Note: Mount backplate with 1" wire entry hole

toward the bottom.  Seal the opening with a

silicone sealant before attaching backplate to surface.

Figure 2b

Seal top 2/3 of case

 to mounting surface.

Side View

Figure 2

Содержание Miniguard HF-2 Series

Страница 1: ...CA 92880 951 371 1730 Facsimile 951 371 2592 October 28 2004 Miniguard HF 2 Series Handsfree Telephone Entry Autodialer INSTALLATION and OPERATIONAL INSTRUCTIONS Firmware revision 020700 Rev A HF2XTRA...

Страница 2: ...fying Autodialed Telephone Number 6 Setting the Site ID Number 7 Changing Program Access Number 7 Setting the Relay Duration Timer 7 Setting Incoming Ring Count 7 Setting Dial Mode 7 Setting Call Legn...

Страница 3: ...omes standard with 2 output relays These relays can be programmed to operate in several different ways Relays can be set to pulse momentarily for camera call up they can be set to stay latched on for...

Страница 4: ...ound wire should go to a grounding rod or grounded metal conduit 5 Trigon recommends that an EMI filter Cornell Dubilier Model APF 1021 or equivalent be mounted between the 12 VAC transformer output a...

Страница 5: ...cabling 250 to 500 ALARM SHUNT IN OUT DSR COM RS 232 CARD READER EARTH GROUND TELEPHONE LINE EARPHONE MOUTH SPEAKER HF 2 MICROPHONE HF 2 MICROPROCESSOR AUDIO SPEAKER VOLUME PRIMARY RELAY 12V AC DC NO...

Страница 6: ...am commands will result in two 2 tones high low signifying their completion and acceptance Standard Mode allows the relays to be activated for a specified time period such as for access control purpos...

Страница 7: ...ust be in Program Mode 2 Press 5 3 Enter the number of rings desired 1 to 9 or 4 Enter 0 if an audible ring is desired from the HF 2 whenever it is called You will hear two beeps indicating command ac...

Страница 8: ...keypad STANDARD MODE When a CALL button is pressed the HF 2 dials a pre programmed phone number and monitors the line for the following signals Busy Signal The HF 2 will hang up and redial the number...

Страница 9: ...UBLE SHOOTING GUIDE TROUBLE SHOOTING GUIDE TROUBLE SHOOTING GUIDE LOSES MEMORY 1 Electrical noise on power line Install EMI RFI filter 2 Excessive electrical noise from strike Use low current strike 3...

Страница 10: ...Program Code r Ring Count 1 2 9 The star key of the telephone The pound sign key of the telephone Tones returned by the unit SECURITY DEPT OPERATION When Security personnel receive a call from the un...

Страница 11: ...ellow Telco White Call Btn White Call Btn 1 2 3 4 5 6 7 8 9 10 11 12 13 Black Speaker Red Speaker 14 15 16 17 18 19 20 21 22 23 24 25 Violet Relay primary Violet Relay primary Orange Relay secodary Or...

Страница 12: ...Page 12 MINIGUARD HF 2...

Отзывы: