background image

www.tridonic.com

2

Subject to change without notice. Information provided without guarantee.

Data sheet 11/20-EM098-7

Emergency lighting units

EM converterLED

   

EL

 

     

 

 

 

Technical data

Rated supply voltage

220 – 240 V

AC voltage range

198 – 264 V

Mains frequency

50 / 60 Hz

LED module forward voltage range

10 – 54 V

Output current

see chapter 5.2

Starting time

< 0.5 s from detection of emergency 
event

Overvoltage protection

320 V (for 48 h)

U-OUT (including open- / short-circuit 
and double load)

60 V

Max. open circuit voltage

60 V

Ambient temperature range ta

-25 ... +55 °C

Max. casing temperature tc

80 °C

Mains voltage changeover threshold

according to EN 60598-2-22

Mains surge capability (between L – N)

1 kV

Mains surge capability (between L/N – PE)2 kV
Type of protection

IP20

Rest mode max. number of emergency 
units

100

Rest mode max. wiring distance

1,000 m

Functional test

Weekly 5s test

Duration test

Yearly 1 h / 2 h / 3 h test

Life-time

up to 100,000 h

Dimensions LxWxH

179 x 30 x 21 mm

EM converterLED ST NiCd/NiMH 50 V

SELFTEST series

 

30

21

30

179

169.2

Position A
   3 h

No duration 
link    2 h

Position B
   1 h

Note: LED Driver supplied with duration link in 3 hours position. Duration link must be set 
before battery and mains connection.

Ordering data

Type

1

Article 

number

Rated 

duration

Packaging, 
carton

Packaging, 
pallet

Weight 
per pc.

EM converterLED ST 202 NiCd/NiMH 50V

 

89800646

1/2/3 h 10 pc(s).

1,600 pc(s).0.073 kg

EM converterLED ST 203 NiCd/NiMH 50V

89800647

1/2/3 h 10 pc(s).

1,600 pc(s).0.073 kg

EM converterLED ST 204 NiCd/NiMH 50V

89800648

1/2/3 h 10 pc(s).

1,600 pc(s).0.073 kg

Test switch EM3

 

A

CCES

-

SORIES

 

Ordering data

Type

Article number

Packaging, 
bag

Packaging,
carton

Weight 
per pc.

Test switch EM 3

 

89899956

25 pc(s).

200 pc(s).

0.013 kg

Status indication bi-colour LED

 

A

CCES

-

SORIES

 

Specific technical data

Type

Rated 

duration

Typ. λ  

(at 230 V, 

50 Hz)

Typ. output 

power 

P emergency

Mains current in charging operation

Rated power in charging operation

Initial charge

Fast recharge

Trickle charge

Initial charge

Fast recharge

Trickle charge

EM converterLED ST 202 NiCd/NiMH 50V

 

1 h

0.60C

1.5 W

15 mA

16 mA

13 mA

1.9 W

2.2 W

1.8 W

2 h

0.65C

1.5 W

19 mA

19 mA

15 mA

2.6 W

2.6 W

2.2 W

3 h

0.65C

1.5 W

19 mA

19 mA

15 mA

2.6 W

2.6 W

2.2 W

EM converterLED ST 203 NiCd/NiMH 50V

 

1 h

0.60C

2.5 W

16 mA

18 mA

13 mA

2.1 W

2.6 W

1.9 W

2 h

0.70C

2.5 W

20 mA

20 mA

16 mA

3.1 W

3.1 W

2.4 W

3 h

0.70C

2.5 W

20 mA

20 mA

16 mA

3.1 W

3.1 W

2.4 W

EM converterLED ST 204 NiCd/NiMH 50V

1 h

0.60C

3.5 W

17 mA

20 mA

14 mA

2.3 W

2.9 W

2.0 W

2 h

0.70C

3.5 W

23 mA

23 mA

17 mA

3.6 W

3.6 W

2.6 W

3 h

0.70C

3.5 W

23 mA

23 mA

17 mA

3.6 W

3.6 W

2.6 W

EM = Emergency

Содержание 89800646

Страница 1: ...rated duration selectable with duration link Constant power output Self test Weekly function test Yearly duration test Driver compatibility 3 pole technology 2 pole LED module changeover and delayed power switching for the LED Driver For further information see chapter LED Driver compatibility Battery management Intelligent charge system Deep discharge protection Polarity reversal protection for b...

Страница 2: ...plied with duration link in 3 hours position Duration link must be set before battery and mains connection Ordering data Type1 Article number Rated duration Packaging carton Packaging pallet Weight per pc EM converterLED ST 202 NiCd NiMH 50V 89800646 1 2 3 h 10 pc s 1 600 pc s 0 073 kg EM converterLED ST 203 NiCd NiMH 50V 89800647 1 2 3 h 10 pc s 1 600 pc s 0 073 kg EM converterLED ST 204 NiCd NiM...

Страница 3: ...bag Packaging carton Weight per pc Test switch EM 3 89899956 25 pc s 200 pc s 0 013 kg Status indication bi colour LED ACCES SORIES Ordering data Type Article number Packaging bag Packaging carton Weight per pc LED EM bi colour 1 0 m CON 89800273 25 pc s 200 pc s 0 015 kg LED EM bi colour high brightness HO 1 0 m CON 89800275 25 pc s 200 pc s 0 015 kg LED EM bi colour 0 6 m CON 89800474 25 pc s 20...

Страница 4: ...erage life time 50 000 hours under rated conditions with a failure rate of less than 10 Average failure rate of 0 2 per 1000 operating hours 3 Installation Wiring 3 1 Wiring diagram One or more LED modules with a total forward voltage of 50 to 250 V can be connected to the EM converterLED module These LED module s marked with Emergency are operated in emergency mode from the associated battery In ...

Страница 5: ...r LED Not connected Not connected Control gear LED LED Control gear Battery Battery LED Module Emergency EM converterLED SELFTEST with one LED module for non maintained emergency operation EM converterLED SELFTEST with a standard LED Driver and one LED module for mains and emergency operation EM converterLED SELFTEST with a standard LED Driver and series operation of LED modules One LED module is ...

Страница 6: ...1 Note The length of LED leads to the LED module must not be exceeded Note that the length of the EM converterLED leads is added to the length of the leads from the LED Driver to the EM converterLED module when considering max permitted lead length of the LED Driver Leads should always be kept as short as possible Maximum lead length for the Test switch and Indicator LED connection is 1 m The test...

Страница 7: ...length 0 3 m 1 0 m Insulation rating 90 C Plug connection Test switch Mounting hole 7 0 mm diameter Lead length 0 55 m Plug connection Battery connection Plug connection 0 3 m Extension 0 5 m Automatic circuit breaker type B10 B13 B16 B20 C10 C13 C16 C20 Inrush current Installation Ø 1 5mm2 1 5mm2 1 5mm2 2 5mm2 1 5mm2 1 5mm2 1 5mm2 2 5mm2 Imax time EM converterLED ST NiCd NiMH 50V 90 130 130 130 1...

Страница 8: ...umber 89800646 2 4 V battery voltage 730 790 mA battery discharge current tolerance EM converterLED ST 203 NiCd NiMH 50V Article number 89800647 3 6 V battery voltage 780 840 mA battery discharge current tolerance LED current mA VLED V VLED V LED current mA EM converterLED ST 204 NiCd NiMH 50V Article number 89800648 4 8 V battery voltage 800 860 mA battery discharge current tolerance LED current ...

Страница 9: ...es specified below The max allowed output current rating of the associated LED Driver is 2 4 A peak current rating of switching relays of EM converterLED The max allowed inrush current rating of the associated LED Driver is 60 A peak for 1 ms or 84 A for 255 μs inrush current rating of switching relay of EM converterLED The max allowed output voltage U OUT of the associated LED Driver applied to t...

Страница 10: ...e interval time is greater than zero automatic test mode enabled The delay timer value set when the unit was commissioned will be reloaded in order to randomise the tests between adjacent units Rest Mode Inhibit Mode Emergency operation is automatically started when the mains supply is switched off If the Rest Mode is activated the discharging of the battery will be minimized by switching off the ...

Страница 11: ...ting LED Driver will recharge the battery normally after running the test of 61347 2 7 CL 22 3 abnormal operating conditions EM converterLED 1 2 3 h Type EM converterLED ST 202 NiCd NiMH 50V EM converterLED ST 203 NiCd NiMH 50V EM converterLED ST 204 NiCd NiMH 50V Article no 89800646 89800647 89800648 Cells 2 cells 3 cells 4 cells Duration 1 h 2 3 h 1 h 2 3 h 1 h 2 3 h Technology and capacity Desi...

Страница 12: ...iMH 2 2 Ah International designation HRMU 23 43 Battery voltage cell 1 2 V Cell type Cs Case temperature range to ensure 4 years design life 5 C to 50 C Max short term temperature reduced life time 70 C Max number discharge cycles 4 cycles per year plus 30 cycles during comissioning Max storage time 12 months 4 0 Ah International designation HRMU 19 90 Battery voltage cell 1 2 V Cell type LA Case ...