7. Battery data

7.1 Battery selection

7.2 Battery charge / discharge data

EM converterLED, 1 / 2 / 3 h, NiMH

Type

EM converterLED ST 

202 NiCd/NiMH 50V

EM converterLED ST 

203 NiCd/NiMH 50V

EM converterLED ST 

204 NiCd/NiMH 50V

Article no.

89800646

89800647

89800648

Duration

1 h

2 / 3 h

1 h

2 / 3 h

1 h

2 / 3 h

Battery charge 

time

Initial charge

20 h

Fast recharge

10 h

15 h

10 h

15 h

10 h

15 h

Trickle charge

continuously

Charging current

Initial charge

110 – 150 mA

280 – 320 mA

110 – 150 mA

280 – 320 mA

110 – 150 mA

280 – 320 mA

Fast recharge

190 – 230 mA

310 – 350 mA

190 – 230 mA

310 – 350 mA

190 – 230 mA

310 – 350 mA

Trickle charge

50 – 90 mA

110 – 150 mA

50 – 90 mA

110 – 150 mA

50 – 90 mA

110 – 150 mA

Discharge current

730 – 790 mA

730 – 790 mA

780 – 840 mA

780 – 840 mA

800 – 860 mA

800 – 860 mA

Charge voltage range

1

0.9 – 1.65 V per cell

Discharge voltage range

1.65 – 1.05 V per cell

1

 

The battery will be charged below 0.9 V. The EM converterLED will indicate a battery fault.

The emergency lighting LED Driver will recharge the battery normally after running the test of 61347-2-7 CL 22.3 (abnormal operating conditions).

EM converterLED, 1 / 2 / 3 h

Type

EM converterLED ST 

202 NiCd/NiMH 50V

EM converterLED ST 

203 NiCd/NiMH 50V

EM converterLED ST 

204 NiCd/NiMH 50V

Article no.

89800646

89800647

89800648

Cells

2 cells

3 cells

4 cells

Duration

1 h

2 / 3 h

1 h

2 / 3 h

1 h

2 / 3 h

Technology 
and capacity

Design

Number 
of cells

Type

Article no.

Assignable batteries

NiCd 4 Ah 
D cells

stick

1 x 2

Accu-NiCd 2A 55

89800092

stick

1 x 3

Accu-NiCd 3A 55

28002773

stick

1 x 4

Accu-NiCd 4A 55

89800089

side by side

3 x 1

Accu-NiCd 3B 55

89800384

side by side

4 x 1

Accu-NiCd 4B 55

89800385

stick + stick

2 + 2

Accu-NiCd 4C 55

28002775

remote box

1 x 3

Pack-NiCd 3D CON

89800389

remote box

1 x 4

Pack-NiCd 4D CON

89800390

NiMH 2.2 Ah 
Cs cells

stick

1 x 2

Accu-NiMH 2A

28002087

stick

1 x 3

Accu-NiMH 3A

28002088

stick

1 x 4

Accu-NiMH 4A

28002089

remote box

1 x 3

Pack-NiMH 2.2Ah 3 CON 28001898

remote box

1 x 4

Pack-NiMH 2.2Ah 4 CON 28001899

NiMH 4 Ah 
LA cells

stick

1 x 2

Accu-NiMH 4Ah 2A CON 28002316

stick

1 x 3

Accu-NiMH 4Ah 3A CON 89800441

stick

1 x 4

Accu-NiMH 4Ah 4A CON

 

89800442

stick + stick

2 + 2

Accu-NiMH 4Ah 4C CON

 

89800438

remote box

1 x 3

Pack-NiMH 4Ah 3 CON

28001896

remote box

1 x 4

Pack-NiMH 4Ah 4 CON

28001897

Содержание 89800646

Страница 1: ...rated duration selectable with duration link Constant power output Self test Weekly function test Yearly duration test Driver compatibility 3 pole technology 2 pole LED module changeover and delayed power switching for the LED Driver For further information see chapter LED Driver compatibility Battery management Intelligent charge system Deep discharge protection Polarity reversal protection for b...

Страница 2: ...plied with duration link in 3 hours position Duration link must be set before battery and mains connection Ordering data Type1 Article number Rated duration Packaging carton Packaging pallet Weight per pc EM converterLED ST 202 NiCd NiMH 50V 89800646 1 2 3 h 10 pc s 1 600 pc s 0 073 kg EM converterLED ST 203 NiCd NiMH 50V 89800647 1 2 3 h 10 pc s 1 600 pc s 0 073 kg EM converterLED ST 204 NiCd NiM...

Страница 3: ...bag Packaging carton Weight per pc Test switch EM 3 89899956 25 pc s 200 pc s 0 013 kg Status indication bi colour LED ACCES SORIES Ordering data Type Article number Packaging bag Packaging carton Weight per pc LED EM bi colour 1 0 m CON 89800273 25 pc s 200 pc s 0 015 kg LED EM bi colour high brightness HO 1 0 m CON 89800275 25 pc s 200 pc s 0 015 kg LED EM bi colour 0 6 m CON 89800474 25 pc s 20...

Страница 4: ...erage life time 50 000 hours under rated conditions with a failure rate of less than 10 Average failure rate of 0 2 per 1000 operating hours 3 Installation Wiring 3 1 Wiring diagram One or more LED modules with a total forward voltage of 50 to 250 V can be connected to the EM converterLED module These LED module s marked with Emergency are operated in emergency mode from the associated battery In ...

Страница 5: ...r LED Not connected Not connected Control gear LED LED Control gear Battery Battery LED Module Emergency EM converterLED SELFTEST with one LED module for non maintained emergency operation EM converterLED SELFTEST with a standard LED Driver and one LED module for mains and emergency operation EM converterLED SELFTEST with a standard LED Driver and series operation of LED modules One LED module is ...

Страница 6: ...1 Note The length of LED leads to the LED module must not be exceeded Note that the length of the EM converterLED leads is added to the length of the leads from the LED Driver to the EM converterLED module when considering max permitted lead length of the LED Driver Leads should always be kept as short as possible Maximum lead length for the Test switch and Indicator LED connection is 1 m The test...

Страница 7: ...length 0 3 m 1 0 m Insulation rating 90 C Plug connection Test switch Mounting hole 7 0 mm diameter Lead length 0 55 m Plug connection Battery connection Plug connection 0 3 m Extension 0 5 m Automatic circuit breaker type B10 B13 B16 B20 C10 C13 C16 C20 Inrush current Installation Ø 1 5mm2 1 5mm2 1 5mm2 2 5mm2 1 5mm2 1 5mm2 1 5mm2 2 5mm2 Imax time EM converterLED ST NiCd NiMH 50V 90 130 130 130 1...

Страница 8: ...umber 89800646 2 4 V battery voltage 730 790 mA battery discharge current tolerance EM converterLED ST 203 NiCd NiMH 50V Article number 89800647 3 6 V battery voltage 780 840 mA battery discharge current tolerance LED current mA VLED V VLED V LED current mA EM converterLED ST 204 NiCd NiMH 50V Article number 89800648 4 8 V battery voltage 800 860 mA battery discharge current tolerance LED current ...

Страница 9: ...es specified below The max allowed output current rating of the associated LED Driver is 2 4 A peak current rating of switching relays of EM converterLED The max allowed inrush current rating of the associated LED Driver is 60 A peak for 1 ms or 84 A for 255 μs inrush current rating of switching relay of EM converterLED The max allowed output voltage U OUT of the associated LED Driver applied to t...

Страница 10: ...e interval time is greater than zero automatic test mode enabled The delay timer value set when the unit was commissioned will be reloaded in order to randomise the tests between adjacent units Rest Mode Inhibit Mode Emergency operation is automatically started when the mains supply is switched off If the Rest Mode is activated the discharging of the battery will be minimized by switching off the ...

Страница 11: ...ting LED Driver will recharge the battery normally after running the test of 61347 2 7 CL 22 3 abnormal operating conditions EM converterLED 1 2 3 h Type EM converterLED ST 202 NiCd NiMH 50V EM converterLED ST 203 NiCd NiMH 50V EM converterLED ST 204 NiCd NiMH 50V Article no 89800646 89800647 89800648 Cells 2 cells 3 cells 4 cells Duration 1 h 2 3 h 1 h 2 3 h 1 h 2 3 h Technology and capacity Desi...

Страница 12: ...iMH 2 2 Ah International designation HRMU 23 43 Battery voltage cell 1 2 V Cell type Cs Case temperature range to ensure 4 years design life 5 C to 50 C Max short term temperature reduced life time 70 C Max number discharge cycles 4 cycles per year plus 30 cycles during comissioning Max storage time 12 months 4 0 Ah International designation HRMU 19 90 Battery voltage cell 1 2 V Cell type LA Case ...

Отзывы: