15
Figure 2-13 External DC Power Cable
Table 2-1 External DC Power Cable Pinout
PIN SIGNAL
NAME COLOR
SPECIFICATION
A, B, E
DC Power
Red
+24 to +32 VDC
C, D
DC Ground
Black
DC Ground
2.3.4
Battery Power Operation
– The battery chargers on the TCR-HHR-02 are only
compatible with BB-2590 Li-Ion batteries.
To ensure a reliable power backup is available during repeater or communications system
operation, apply an external power source (AC or 24 VDC) prior to use to charge the
onboard batteries. It will take 8-10 hours to completely charge all four battery sections
(2/battery) from a completely discharged state.
Although the BB-2590 Li-Ion rechargeable batteries have a high number of
charge/discharge cycles, they should be monitored for charge maintenance over their life
time and replaced if they exhibit uncharacteristic Amp hour (6.2Amps/hour) performance
degradation.
Table 2-2 Power Control Matrix
Note:
A good battery section is indicated by a flashing green CELL LED on the DC
power control module (refer to Figure 1-4). A flashing red CELL LED indicates that
the battery section has fallen below the acceptable cell voltage (approximately 11
VDC) and the battery needs to be recharged.
Power Source
Battery Charge
Radio Power
PA Power
AC-DC
YES (with system
ON or OFF)
YES (with system
ON or OFF)
YES (with system ON
only, up to 50 Watts)
12 VDC
NO
YES (with system
ON or OFF)
YES (with system ON
only, up to 25 Watts)
24 VDC
YES (with system
ON or OFF)
YES (with system
ON or OFF)
YES (with system ON
only, up to 50 Watts)
1 Good Internal
Battery Section
N/A
YES (with system
ON only)
NO
2 Good Internal
Battery Sections
N/A
YES (with system
ON only)
YES (with system ON
only, up to 25 Watts)
3 Good Internal
Battery Sections
N/A
YES (with system
ON only)
YES (with system ON
only, up to 25 Watts)
4 Good Internal
Battery Sections
N/A
YES (with system
ON only)
YES (with system ON
only, up to 25 Watts)
Содержание TCR-HHR-02
Страница 17: ...11 DC POWER CONTROL RAD1 RAD2 Figure 2 10 TCR HHR 02 Repeater System Signal Flow Block Diagram ...
Страница 18: ...12 PELICAN CASE ENCLOSURE Figure 2 11 TCR HHR 02 Communications System Signal Flow Block Diagram ...
Страница 19: ...13 50 TX Antenna RX Antenna Figure 2 12 Typical Tactical Repeater Setup ...