Страница 1: ...Lemon 5 ...

Страница 2: ......

Страница 3: ...nment otherwise it will lead to fire or explosion When the fusion splicer is working do not touch the electrode avoid the hurt caused by the discharge of the electrode When replacing the electrode you must turn off the power and disconnect the power cord Please follow the operation manual strictly to use the battery Please do not charge the battery by using methods other than in the manual Don t t...

Страница 4: ...d to strong vibration and shocks otherwise the machine will be damaged Please use a dedicated carrier to transport or store the fusion splicer Using the battery The equipment can use a disposable alkaline battery or rechargeable battery and cannot be mixed with different types or different capacity batteries Only rechargeable batteries can be charged Avoiding condensation Sudden changes in tempera...

Страница 5: ...Standard Package 3 Carrying case Spare electrode Cooling tray Calibration certificate Fiber cleaver Fiber stripper AC DC adapter CD ...

Страница 6: ...ti collision batten 8 Heater V groove V groove Clamp slot Hand strap USB port 4 3 inch TFT color LCD 7 Electrode Cover LED 10 Multi function clamp 9 Heater cover Optical fiber presser 13 Windshield cover 4 9 10 1 2 3 4 5 6 7 8 11 18 OPM VFL port 18 16 15 14 12 13 17 19 19 Screen Cover Host ...

Страница 7: ...eating Motor reset Navigation buttons Move the cursor fiber Modify settings Start splicing 5 Enter Save settings Save splice image Switch X Y images Discharge How to Use Keyboard Back to previous menu Note Also can be operated by touch screen ...

Страница 8: ...Cleaning and Cleaving fiber Loading fiber onto splicer Confirming splicing mode automatic splicing when windshield cover closed Visual inspection on LCD during splice Tension Test Splicing Operation Taking out spliced fiber Centering sleeve to spliced point Centering sleeve in heater Start heating Press to save the splice image HEAT ...

Страница 9: ...7 Press to turn on the device then enter into the READY interface in default and display the present splice and heat mode settings 52 READY ...

Страница 10: ...press to enter OPM VFL measurement interface then tap corresponding icons to operate And press to back to READY Interface Set reference value Switch unit dBm dB Blink OFF Wavelength 850 1300 1310 1490 1550 1625nm Ref setting Unit VFL ON 8 ...

Страница 11: ...9 Press to enter the main menu then using navigation buttons to choose the different sub menus and press to enter each interface then press back to main menu Main Menu 52 ...

Страница 12: ...Splice Mode 10 In Splice Mode user can press to choose and to directly use the selected splice mode then it turns red when selected 52 ...

Страница 13: ...the parameters at will 52 Set the pre discharge time before final splicing Set pre discharge power before final splicing Set splicing time Set splicing power Set the distance of left and right fiber end face Set the limit value of fiber end surface angle Core Profile Alignment Set the overlap length of fiber propel when splice ...

Страница 14: ...n Heat Mode user can select protection sleeve length based on requirement Then press to enter parameter edition interface to set heat time temperature and auto heat ON OFF 52 52 Range 0 240s Range 130 200 Open Close ...

Страница 15: ...d to edit ON OFF for each function If Open it will auto splicing when close the cover If Open it will auto reset the motor after splicing Open Close auto arc calibration after splicing If Open it will stop 1 or 2 times during the splicing and press SET to continue ...

Страница 16: ...Setting 14 In Setting interface Restore factory settings Other settings are protected with passwords 52 52 2021 9 6 14 28 52 52 ...

Страница 17: ...Maintenance 15 52 ...

Страница 18: ...red bare fiber to V groove close the cover then arc calibrate starts automatically If prompt Please continue please do same operation as above until auto calibration finish Note Only do ARC calibration when device comes to large changes on discharge power spliced points with depressions or bubbles ...

Страница 19: ...lean or not and indicate dust position No need place fiber choose Dust check Press to enter the interface press again to start checking If prompts Dust please clean objective lens light source surface in the windshield cover If still not work pls contact the manufacturer ...

Страница 20: ...Maintenance Electrodes 18 Aging Electrode is used for stability testing of new electrode Users can check ARC Times and Total ARC Times and can clear ARC Count 52 0010 ...

Страница 21: ...uch screen correction 19 In Sensor Value it will show the environmental condition such as temperature air pressure power voltage In Touch screen correction follow the prompts to adjust the screen 52 33 69 32 00 1000 1hpa 15 10 9V ...

Страница 22: ...2 Image brightness tap to adjust the image brightness and to switch the image to be adjusted 3 Discharge press to discharge 4 Fiber angle place a fiber to fill the screen press to display the tilt angle of the fiber 5 Window movement user can move the position of the optical fiber in the image window Note This function is mainly for maintenance do not operate at random ARC ...

Страница 23: ...Information 21 In Information interface user can check spliced data and the device information 52 ...

Страница 24: ...choose the record to check the detailed splice information and to delete data or other options The splice records will be saved automatically after splicing 52 Jump to the first record Jump to the last recent record Clear selected record Clear all records 52 ...

Страница 25: ...Information Splice Image 23 In Splice Image press to choose the image data to view the splice image and to delete data or other options The splice image should be saved by pressing after splicing 52 52 ...

Страница 26: ... 24 1 Connect U disk to the fusion splicer through the OTG cable 2 Choose Export records and press to enter and press again to connect 3 The records will be transmitted automatically turn off the device and unplug the U disk 52 ...

Страница 27: ... U disk to the fusion splicer through the OTG cable 3 Turn on the device and choose Information then Software Update It will upgrade automatically and restart after upgrade completed Then turn off the device and unplug the U disk Ready to connect USB disk FATES OK U Disk Total Size 479MB U Disk Free Size 465MB Please waiting Starting app now File update succeeded ...

Страница 28: ...26 Steps 1 Loosen the screws and remove the electrode cover 2 Remove the old electrode and install a new one 3 Install the electrode cover and tighten the screws Note Keep the device off and ensure no fiber in the clamp slot ...

Страница 29: ...cer Cleaning 27 V groove Fiber Presser Heater Objective Lens When cleaning keep the device off Use cotton swab moistened with purity alcohol Do not touch the electrode tips Use dry swab to clean the excess alcohol ...

Страница 30: ...r Increase the splice power and or splice time Poor quality of fiber end face Dust still exists after cleaning the fiber or discharge Poor quality of fiber end face Low prefuse power or short prefuse time Small overlap High prefuse power or long prefuse time Large overlap or low prefuse power Inappropriate splicing power Some inappropriate splicing parameters Some inappropriate splicing parameters...

Страница 31: ......