FIELD METERS MCT 080 / 081 / 082 / 085 USER MANUAL
p.
80
14.2 Satellite band
14.2.1 Launching
Setting the remote power supply to satellite:
Configuration lines:
ON
to turn on the
remote power
supply under
satellite measure
OFF
to turn off the
remote power supply
under satellite measure
AUTO
to launch
automatically the
remote power supply
in satellite measure
mode even after
shutting off
-
LO frequency:
LO
frequencies for low and high
bands
LO selection:
band commutation
on the LNB (22kHz, ToneBurst or
DiSEqC)
-
Polar selection:
polarization
commutation on the LNB (13/18V
or DiSEqC)
-
DCSS:
Digital Channel Stacking (2
modes SATCR and SCD2 single
cable distribution)
-
Switch:
switch type and position
(No, ToneBurst, 22kHz, DiSEqC,
Pos A, B, C or D)
-
Uncommitted:
"Uncommitted" switch
type and position (No, DiSEqC, Pos 1 to
16)
-
Positioner:
presence of a positioner
(Yes / No)