![background image](http://html1.mh-extra.com/html/triax/492055/492055_user-manual_1160805021.webp)
21
Rev. 01 - 2014 - E
Click OK to return to the Configuration window.
Note
The services you have selected will no longer
be available in the TDX-pool for other output
modules.
Services from input module
To select the services from a particular input module,
open the drop-down list of the Select input field and
select “Transparent” from the list.
TDX Service Tool
Click the Services... button to open the Select input
modules window.
Click the checkbox of the module you want to use.
If you want to give your selection of services a name,
enter the name in the Mux name field.
Click OK to return to the Configuration window.
Next you select or enter values in the other fields in the
Configuration window.
RF level correc-
tion
To select another RF level correction, open the drop-
down list and select the level you want to use.
Symbol rate
Enter the desired symbol rate (from 3150 to 7200 kS) in
the Symbol rate field.
QAM mode
To select which QAM mode to use, open the drop-
down list and select the QAM mode you want to use.
Transportstream
ID
By default each QAM output has an automatically as-
signed transport stream ID. It is possible to change the
ID.
Note
Each QAM output in your TDX headend sys-
tem must have a unique transport steam ID.
891076E_492055_492056_TDX_QAM_module - User Guide - EN.indd 21
17-01-2014 11:25:51