15
TDX Service Tool
When you display the Configuration window for an input module
that has been configured, all fields are filled in and services have
been selected.
If you want to change the existing frequency, polarity, services just
follow the same procedure as when you configure an input mod-
ule for the very first time.
Note
Status informa-
tion
Status information is placed at the bottom of the Configuration window. The
information displayed in the configuration window of a DVB-S module in-
cludes the status of the module, bit error rate, locked frequency, TS symbol
rate and revision of software.
Status
Informs you whether the input module is locked or not.
Bit error rate
Informs you of the rate at which errors occur in the
transmission.
Locked frequency Displays the actual frequency that the input module
has locked into.
Remember to click the Apply button in the upper right-hand corner to save
new settings in the configuration.
TS symbol rate
Displays the actual symbol rate.
SW revision