![TriangleTube Delta Elite F-25 Скачать руководство пользователя страница 7](http://html1.mh-extra.com/html/triangletube/delta-elite-f-25/delta-elite-f-25_instructions-manual_1160049007.webp)
Delta ELITE Combination Heater
Oil-Fired Direct Vent Instructions
F-Model
Burner
Standard
Standard
Air Tube
Overfire
Air
Head
Head
Input
Combustion Combination Combination
Draft
Setting
Type Setting
No. 2 Oil
Control
Control
GPH
F-25
0.70
AFG
R7184P
AFG50MB
0.02
25.0
L1
--
F-30
0.85
AFII-150
R7184P
HLX70HD
0.20
6.5
HLX6
4.0
F-35
1.00
AFII-150
R7184P
HLX70HD
0.23
7.0
HLX6
7.0
Oil Burner Nozzle Data
Nozzle/
Primary Nozzle
Alternate Nozzle
Pump
Oil Pump
Gear
F- Model
Size
Angle
Type
Size
Angle
Type
Pressure
Model
Capacity
GPH
GPH
PSIG
GPH
F-25
0.5
60
B-Delavan
200
Clean Cut
3/17
F-30
0.65
45
B-Hago
0.65
45
AS-DanFoss
175
Clean Cut
3/17
F-35
0.75
45
AS-DanFoss
0.75
45
B-Delavan
175
Clean Cut
3/17
Beckett AF II
Beckett AFG
•
Oil ratings based on No. 2 fuel oil with heating value of 140,000 Btu per gallon.
•
R7184P combustion safety control uses a cadmium sulfide cell flame detector to monitor oil
flame, provides intermittent direct spark ignition of oil flame and pre purge cycles.
•
Settings shown are for initial start-up. Final settings should be determined after combustion readings.
7
DESCRIPTION
AFII-150
AFG
Depth of Burner Chassis
6 11/16”
6 9/16”
Insertion Depth (Air Tube to Flange)
3"
2 3/4"
Motor Size - HP / RPM
1/7 HP 3450 RPM 1/7 HP 3450 RPM
Power Supply
120/60/1
120/60/1
Motor Amps
1.8A
5.8A
Burner Pitch
6º
3º