Delta ELITE Combination Heater

Oil-Fired Direct Vent Instructions

Vent Pipe Installation (

see Fig. 1-2

)

Vent Terminal Assembly

1. Determine proper location of the vent termina-

tion and cut an opening in the wall as follows:

– Combustible wall:  8 inches diameter.

– Non-combustible wall:  8 inches diameter.

2. Secure the trim plate flashing to the outside

wall.

3. Insert the terminal assembly through the trim

plate opening from the outside, until the stop
bead on the assembly is flush with the trim
plate.

4. Insert the inside trim plate over the terminal

assembly and secure it to the inside wall.

5. Tighten the band clamp on the inside trim plate,

securing the terminal assembly.

6. Seal around the outside trim plate and all exter-

nal joints with a weatherproof caulk.

Vent Pipe

1. Measure and cut the vent pipe to length.  Use a

hack saw with a fine tooth blade.

2. Install the Terminal Connector and Appliance

Adapter to the vent pipe.

Note:

Insert the vent pipe through the Air Intake
Adapter prior to install the Terminal Connector
and the Appliance Adapter

– Apply a continuous bead of high tempera-

ture sealant around the outside of the corru-
gated pipe on the Appliance Adapter.

– Insert the adapter into the end of the vent

pipe using a twist motion.  Turn the adapter
counter-clockwise until it is insert into the
vent pipe a minimum of 4 inches.  The
outer collar of the adapter should overlap
the outside of the vent pipe.

– Tighten the band clamp on the outer collar

of the Appliance Adapter securing it on the
vent pipe.

– Repeat the above steps with the Vent

Connector.

Connecting the Appliance Adapter to the unit

1. Apply a continuous bead of high temperature

sealant to the inside of the Appliance Adapter
approximately 1/4” to 1/2” from the adapter
edge.

2. Slip the Appliance Adapter over the outlet of the

flue hood and tighten the band clamp.

DO NOT install a barometric damper. A baro-
metric damper is not required on direct vent
applications.

Terminal Connector to Terminal Assembly

1. Apply a continuous bead of high temperature

sealant on the inside of the Terminal Adapter
approximately 1/4” to 1/2” from the end.

2. Slip the adapter over the Terminal Assembly

until it is fully engaged.  Tighten the band clamp
securing the adapter to the Terminal Assembly.

Air Inlet Adapter to Terminal Assembly

1. Apply a continuous bead of Silicone sealant

(high temperature sealant is not required) on the
inside of the Air Inlet Adapter approximately
1/4” to 1/2” from the adapter end.

2. Slip the Air Adapter over the Terminal

Assembly until it is fully engaged. Tighten the
band clamp securing the Air Inlet Adapter to the
Terminal Adapter.

3, Apply a continuous bead of silicone sealant

(high temperature sealant is not required) seal-
ing the gap around the vent pipe and the Air
Inlet Adapter.

Securing The Vent Pipe

Secure the vent pipe into position using strap
hangers.

Space the hangers appropriately to avoid any
sags or dips in the vent pipe.  A maximum 5 feet
spacing is recommended.

Ensure all bends in the vent pipe are less than 90º.

All horizontal run must slope towards the vent
terminal at least 1/4 inch per foot.

WARNING

2

Содержание Delta Elite F-25

Страница 1: ...view Prevailing winds could cause freezing of con densate and water ice build up may occur on building plants or roof Location of the Vent Termination Locate or guard the vent termination in a manner...

Страница 2: ...of the Appliance Adapter securing it on the vent pipe Repeat the above steps with the Vent Connector Connecting the Appliance Adapter to the unit 1 Apply a continuous bead of high temperature sealant...

Страница 3: ...disconnected and oil supply valve is closed prior to any service Refer to the HMF Installation and Technical manual for additional servicing and cleaning instructions Venting and Air Inlet Systems In...

Страница 4: ...Specialists Push Butto n T o Reset Switch Phas e I I I P h a s e I I I P h a s e I I I P h ase III c i t semoD S p a c e h e a t i n g Phas e I I I P h a s e I I I P h a s e I I I P h ase III c i t s...

Страница 5: ...lta ELITE Combination Heater Oil Fired Direct Vent Instructions Vent termination assembly Inside trim plate with band clamp Outside trim plate Appliance adapter Vent terminal adapter 5 Air Inlet Adapt...

Страница 6: ...Single Wall Flex Air Inlet Duct Appropriate Length High Temperature Sealant Banding Clamps Vacuum Relief Valve Item No Delta ELITE Burner Model Part Number Model 1 F 25 30 35 Carlin EZ 1 HMBUR35 2 F...

Страница 7: ...avan 200 Clean Cut 3 17 F 30 0 65 45 B Hago 0 65 45 AS DanFoss 175 Clean Cut 3 17 F 35 0 75 45 AS DanFoss 0 75 45 B Delavan 175 Clean Cut 3 17 Beckett AF II Beckett AFG Oil ratings based on No 2 fuel...

Страница 8: ...0 W Delavan 0 65 60 B Hago 150 A2VA73006 3 17 F 35 0 85 70 B Delavan 0 85 60 W Delvan 150 A2VA73006 3 17 Oil ratings based on No 2 fuel oil with heating value of 140 000 Btu per gallon CCT combustion...

Страница 9: ...il Air Turbulator Overfire GPH Setting Setting Draft F 25 BF 3 0 70 6 0 1 0 0 01 F 35 BF 5 0 85 5 0 1 0 0 01 F 35 BF 5 1 00 7 0 2 0 0 01 Oil Burner Nozzle Data Primary Nozzle Alternate Nozzle Pump F M...

Отзывы: