37
To ensure safe and efficient operation of the
appliance, the boiler
must
be serviced at least once a
year by a CORGI-registered engineer. Failure to do so
will invalidate the guarantee.
Before and after servicing, a combustion analysis
must be performed, in accordance with the
instructions given in
section 10
,
page 35
.
To access the internal chamber of the boiler, refer to
section 4
,
page 16
.
Before carrying out any work on the gas-carrying
parts, always switch off the supply to the appliance.
Always isolate the electrical supply to the boiler before
carrying out any work on electrical components.
-
Call up the last fault stored by the appliance onto
the multifunction display (see
section 7.4
,
page
33
for visualisation codes).
-
The display will now show the last fault to occur
with the boiler (see
section 13.1
,
page 40
for fault
codes). It should then be ascertained whether this
fault was rectified. Carry out any action as
necessary.
-
Perform a visual check of the flue and associated
seals for evidence of gaps and splits. Repair as
necessary.
-
Check the gas supply pressure against the figures
specified on the technical specification table
(
section 2
,
page 7
).
-
Check the combustion analysis figures for the
CO
2
against those given in
section 10
,
page 35
.
-
Check the gas and water systems for leaks.
-
On the combi (CB) model only, check the hot
water outlet temperature does not exceed that
given on the technical specification table.
-
Check and clean the burner and heat exchanger
(see
section 12.2
,
page 38
).
-
Remove the condensate trap pipe (
item 9
,
fig 47
)
from the bottom plate (
10
). Remove bolt (
11
) and
the bracket (
12
).
-
Disconnect the condensate bottom plate by
pulling downwards, then away from the right side
of the shaft (
13
).
-
Clean the condensate trap by unscrewing the
plastic cover on the underside of the boiler. Check
inside for deposits and clean as necessary. Refill
to halfway with water.
-
Check all condensate run-off pipework for leaks.
-
Check that the pressure charge of the expansion
vessel matches that given on the technical
specification table (
section 2
,
page 7
).
-
Check the central heating water pressure. If
outside required parameters, adjust as necessary
(see
section 3.6
,
pages 13/14
).
-
Visually inspect the wiring to the appliance for
physical damage.
-
Check the programmer settings are to those
required by the user.
-
Check the peripheral controls for correct operation.
-
Refit all components in reverse order, ensuring
that all seals are checked for damage and
replacing if necessary.
12 SERVICING AND MAINTENANCE
12.1 SERVICE PROCEDURE
Содержание TRISTAR OPTIMA JUNIOR K CB
Страница 2: ...2...
Страница 4: ...4...
Страница 7: ...7 2 TECHNICAL SPECIFICATION...
Страница 9: ...9 2 2 WALL MOUNTING TEMPLATE FIG 2...
Страница 28: ...28 6 16 VERTICAL BALANCED FLUE SCHEMATIC FIG 39...
Страница 32: ...32...
Страница 42: ...42...
Страница 43: ...43...
Страница 44: ...44 Issue 1 Rev 0 July 2005 Item No 510062 LB 1480 01 09 2005...