10
INSTALLATION
INSTALLATION
Regulations
Installation of the boiler must comply with the following British Standards and Regulations:
BS5449 – Forced circulation hot water central heating systems.
BS7074-Part 1: Code of practice for sealed water systems.
The Building Regulations: Part ‘L’ (Northern Ireland)
Current I.E.E. Regulations
Local water undertaking By-laws.
This boiler incorporates an Unvented Cylinder. Unvented cylinders are a controlled service as defined in the latest edition of
the building regulations and should only be fitted by a competent person.
England and Wales - Building Regulations G3
Scotland – Technical Standard P3
Northern Ireland – Building Regulation Part F
Health and Safety at Work Act
The installer should be aware of his responsibilities under the Act and provide where necessary, appropriate protection for
persons carrying out the installation. In the interests of safety, a competent engineer should install the boiler and all wiring must
be carried out in accordance with current IEE regulations.
IMPORTANT
ALL ELECTRICAL WORK MUST BE CARRIED OUT BY A QUALIFIED ELECTRICAL ENGINEER TO CURRENT IEE WIRING
REGULATIONS.
UNPACKING THE BOILER
Carefully open the boiler carton, remove boiler and place in a safe place until required.
NOTE: ALWAYS STORE THE BOILER IN A DRY PLACE PRIOR TO FITTING.
SITING THE BOILER
IMPORTANT: NOT TO BE INSTALLED IN A SHOWER COMPARTMENT OR BATHROOM
Ensure adequate clearance is allowed for making water connections. Access is required to the front of the boiler for servicing.
The boiler must also be fitted in a dry well-ventilated position, which is not subject to adverse temperature conditions. (See
ventilation requirements).
Care should be taken when siting the appliance to make sure adequate access is available for future servicing of the appliance.
Please note that the PCB and heat exchanger assembly may require removal during such times.
The front cover is held in position by four Phillips Head screws, two at the top and two at the bottom. Clearance at the top and
bottom of the boiler should be adequate to allow access with a small Phillips screwdriver.
When removing the cover please unplug the cable between the display and main circuit board.
The boiler must be mounted on a suitable wall capable of bearing the weight of the boiler.
Utilise all 6 fixing points on top and bottom fixing brackets.