2.1 Intended use
Servo drives are safety components for installation into stationary electric, industrial machines and
commercial systems.
Safety Information
CAUTION
The manufacturer of the machine must produce a risk assessment for the machine and take
appropriate measures to ensure that unforeseen movements do not result in personal injury
or material damage.
Cabinet
The servo drive must only be operated in a closed control cabinet, as defined in chapter 5.8, which may
also require ventilation or cooling.
Power supply
The drive must be connected to a compatible power supply. Possible devices are Triamec TP80 for
TSD80 Drives and Triamec TP130 for TSD130 Drives. Power supply must be galvanically isolated from
the supply mains. Connection to power supplies is described in chapter 7.4.2.
Motors
The TSD80/TSD130 family of servo drives is exclusively intended for driving suitable synchronous servo-
motors, asynchronous motors, voice coil and DC motors.
Safety
Observe the chapter 5.5 when you use the safety function STO.
2.2 Prohibited use
Other use than described in chapter 2.1 is not intended and can lead to injured persons or damage of
equipment. The use of the servo drive in the following environments is prohibited:
potentially explosive areas
environments with corrosive and/or electrically conductive acids, alkaline solutions, oils, vapors,
dusts
Commissioning the servo drive is prohibited if the machine in which it was installed,
does not meet the requirements of the EC Machinery Directive
does not comply with the EMC Directive or with the Low Voltage Directive
does not comply with any national directives
The control of holding brakes by these servo drives alone may not be used in applications, where per -
sonnel security is to be ensured with the brake.
2.3 Responsibility
Electronic devices are never fail-safe. The company setting up and/or operating the machine or plant is
itself responsible for ensuring that the drive is rendered safe if the device fails.
The standard IEC 61800-5-2 'Safety of machines' stipulates safety requirements for electrical controls.
HWTSD80-TSD130_4_HardwareManual_EP006
2022-01-27
7/49