TRI02SYS 02LINE 10020110 Скачать руководство пользователя страница 6

 
 

  

TOC2001NUbb_0620

 

 

      

           6/6 

TRI

0

2

SYS

 sarl 

 

300 Rue des Arts et Métiers, 21410 PONT DE PANY

 

 

6.4 Repeater 2 levels function 

 

The repeater function of the 4 channels receiver is used to increase the range between 

0

2

LINE

 

transmitters  and  receivers.  When  the  radio  signal  from  a  transmitter  is  received,  it  is 
retransmitted to the associated receiver via a  maximum of two repeaters. Radio signals are 
received and transmitted automatically. 

  

 
 
 
 
 
 
 
 
 
 

a) On the receiver, activate the slave RTL mode by a short press (approximately 0,5s) on 

LRN

 and 

CLR

 simultaneously. This mode is confirmed by the regular flashing (orange) 

of the 4 

LEDs

; then short press (approximately 0,5s) 

CLR

. This mode is confirmed by the 

red 

LED 1

 flashing. 

b) The current configuration is displayed by the number of 

LED 1 

flashing: 

   

1

- repeater off           

2

 - activated repeater, level 1         

3

 - activated repeater, levels 2 

c) To change the mode of operation of the repeater, short press 

CLR

 the number of times 

corresponding to the desired mode (b). Each press is acknowledged by maintaining 

LED

 

on for the time of the press. The new configuration is stored and enabled, after 1,5s 

without any press. As soon as the flashing restarts, the new configuration is displayed 
and editable again (back to b). 

d) To exit this function, short press (approximately 0.5s) on the 

LRN

 button. The output is 

confirmed by stopping the flashing of 

LED 1

. In the absence of activity, this function stops 

automatically after 30 seconds. 

 

Note: 

-  This function is disabled on delivery of the receiver. 

 

6.5 Current safety function 

 

When  an  overcurrent is detected  on  one  or more  receiver  outputs,  a  flashing red 

LED

  fault 

informs the user of the concerned output(s). The receiver then deactivates the accused outputs 
and the red 

LED(s)

 flashes until the user has cleared the fault. 

To clear the fault, press (approximately 0.5s) the 

CLR

 button. No reprogramming is necessary 

for restarting. Checking the electrical connection and the connected loads is essential. 
 

Note: 

- The value of the detection threshold is not configurable (factory value). 
 

 

 

 

 

 

    

7.1 New or existing installation 

 

  Check  the  circuit  breaker,  the  electrical  supply  and  the  load  connected  to  the  receiver 

associated with this sensor (qualified electricians). 

  Check the connected load and the connecting cables (qualified electricians). 

  If  the  receiver  functions  at  a  shorter  distance  relative  to  the  sensor,  it  is  subject  to 

interference or used outside the transmission range. 

  Search the system environment for changes that could cause the interference (for example 

movement of metallic cabinets, furniture or partitions). 

  Use the sensor or receiver in a more suitable location. 

  Clear the receiver and perform a new learn process. 

 

7.2 Automatic activation of the receiver 

 

  The cause may be the activation of a sensor external to the system which has by chance 

been programmed on the receiver. 

  Clear the receiver and perform a new learn process. 

 

7.3 Limitation of the range of the radio signals 

 

  Transmitter/receiver used close to metallic objects or close to materials containing metallic 

elements. Observe a distance of at least 10 cm. 

  Humidity in the materials. 

  Device  emitting  high  frequency  signals  such  as:  audio  and  video  systems,  computers, 

electronic ballasts or fluorescent tubes. Observe a distance of at least 0.5 m. 

 

7.4 Contacts 

 

E-mail : ............................ 

[email protected] 

 

 

 

 

 

 

 

  

 

In accordance with European Directive 2012/19 / EU on waste electrical and 
electronic equipment and its implementation in accordance with national laws, 
this logo means that devices must not be thrown away with household waste. 
The hazardous substances they are likely to contain can harm health and the 
environment.  Have  these  devices  taken  back  by  your  distributor  or  use  the 
selective collection means made available by your municipality. 
 

 

 

    

 
 
This product can be marketed and distributed in the countries of the European Union. Hereby 

TRI

0

2

SYS 

declares that radio equipment 

10020110

 is in compliance with directive 2014/53/EU, 

known as the RED Directive. 
The full text of the EU declaration of conformity is available at the following internet address:

 

www.trio2sys.fr

 . 

 
                                                                                                                 D.Girard

       

 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 7. Troubleshooting 

 9. Declaration of conformity 

 

 8. Recycling of the device 

 

 

Receiver 

Содержание 02LINE 10020110

Страница 1: ...une utilisation conforme à sa destination Toute intervention ou modification par l utilisateur est interdite Ne pas l utiliser en liaison avec d autres appareils dont le fonctionnement pourrait mettre en danger les personnes les animaux ou les biens 1 La tension de sortie du récepteur 4 canaux est la même que la tension d alimentation 2 Nous consulter pour d autres types de charges 3 Pour des puis...

Страница 2: ...tuator Measurement Response contenant les données de consommation 5 3 2 Remise à zéro des données de consommation Mettre l appareil hors tension Maintenir enfoncé le bouton CLR puis mettre sous tension l appareil Une fois la LED 1 orange fixe attendre le passage de la LED 1 en rouge 5s puis relâcher le bouton CLR Appuyer sur le bouton LRN environ 1s pour remettre à zéro les valeurs enregistrées du...

Страница 3: ...ur du seuil de détection n est pas paramétrable valeur usine 7 1 Installation nouvelle ou existante Vérifier le coupe circuit l alimentation électrique ainsi que la charge connectée au récepteur associé à ce capteur électriciens professionnels Vérifier la charge connectée et les câbles de connexion électriciens professionnels Si le récepteur fonctionne à une distance plus courte par rapport au cap...

Страница 4: ... repairs or modifications by the user are forbidden Do not use with other devices the operation of which could endanger people animals or property 1 The output voltage of the 4 channels receiver is the same as the supply voltage 2 Consult us for other types of charges 3 For powers greater than 10W 4 Power consumed without activation of the relays Note The signal strength between the transmitter an...

Страница 5: ...ment Response frame containing the consumption data 5 3 2 Reset consumption data Switch off the device Hold down the CLR button then switch on the device Once the orange LED 1 is fixed wait for the LED 1 to go red 5s then release the CLR button Press the LRN button for about 1s to reset the recorded values of the receiver to zero the red LED goes out to confirm the erasure of the data 5 For more d...

Страница 6: ...ion threshold is not configurable factory value 7 1 New or existing installation Check the circuit breaker the electrical supply and the load connected to the receiver associated with this sensor qualified electricians Check the connected load and the connecting cables qualified electricians If the receiver functions at a shorter distance relative to the sensor it is subject to interference or use...

Отзывы: