TRI02SYS 02LINE 10020110 Скачать руководство пользователя страница 4

 
 

  

TOC2001NUbb_0620

 

 

      

           4/6 

TRI

0

2

SYS

 sarl 

 

300 Rue des Arts et Métiers, 21410 PONT DE PANY

 

 

 
 
 
 
 
 
 

  

1.1 Use 

The  modular  4  channels  switch  receiver 

0

2

LINE 

10020110 

is used to receive radio signals from switch 

transmitters  or 

0

2

LINE

  sensors  (see  compatibility 

table §6.1). Designed for switching LED and compact 
fluorescent lighting loads, it can also switch resistive 
loads  (halogen),  fluorescent  tubes,  TBT  halogen 
lamps with ferromagnetic and electronic transformer, 
power contactors or small motors. 
The  4  channels  switch  receiver is  equipped with  the 
« repeater »  function  as  well  as  the  « consumption 
indicator » function (see §5.3 and §6.4). 
Before  use,  the  transmitters  must  be  assigned  to  a 
receiver.  Each  sensor  or  transmitter  can  control  an 
unlimited number of receivers. 
 

Note: 

Read  the  user  manual  carefully  before 

commissioning. 

To 

consult 

the 

consumption 

indications,  it  is  recommended  to  connect  the  4 
channels  switch  receiver  10020110  with  a  suitable 
software. 

 

    

1.2 Guarantee terms 

 

This operating manual is an integral part of the device and our guarantee terms. It must always 
be delivered to the user. We reserve the right to modify the technical design of these devices 

without warning. 

TRI

0

2

SYS

 products are manufactured and their quality checked by making 

use of the latest technologies and taking into account the applicable national and international 

directives.  If  nevertheless  a  fault  arises,

  TRI

0

2

SYS 

undertakes  to  remedy  the  default  as 

follows, without prejudicing the rights  of the end customer that arise from the sales contract 
with his reseller: 

If the event of exercising of a legitimate and regular right, 

TRI

0

2

SYS

, may at its sole discretion, 

rectify the device fault or supply a fault-free device. Any claim beyond this and all claims for 
consequential damages are excluded. 
A legitimate fault exists if the device cannot be used at the time of delivery to the end customer 
because  of  a  design  or  manufacturing  defect  or  if  its  practical  use  is  severely  limited.  The 
guarantee is void in cases of natural wear and tear, incorrect use, incorrect connection, where 
the device has been repaired or external influence. The guarantee period is 24 months (from 
the date of invoicing). French law applies to the regulation of guarantee rights. 

 
 

 

 

 

 

 

  

WARNING!  Risk  of  electric  shocks!  (See  UTE  C18-150)  The  device  contains 
live internal components. Risk of wounds or injuries if contact occurs! All work 
on  the  mains  supply  network  and  the  device  must  only  be  carried  out  by 
authorised professional technicians. 

  Before carrying out any work, switch-off and isolate the device. 

  Secure the device to prevent it being switched back on. 

  Check the device is in a zero-volts state.   

  Carefully reclose the casing before reconnecting to mains power.

 

  

Observe the following points: 

  The laws, standards and directives in force. 

  The device operating manual and best practice at the time of installation. 

  An  operating  manual  can  only  give  general  instructions.  They  must  be  interpreted  in  the 

context of a specific installation. 

The device is intended solely for use conforming to its purpose. Any repairs or modifications 
by the user are forbidden! Do not use with other devices the operation of which could endanger 
people, animals or property. 

 

    

 

  

 
 
 

 
 

 
 
 
 
 
 
 
 
 
 
 

 

 
 
 
 
 
 
 
 
 
 
 
 

-1-

 The output voltage of the 4 channels receiver is the same as the supply voltage. 

-2-

 Consult us for other types of charges. 

-3-

 For powers greater than 10W. 

-4-

 Power consumed without activation of the relays. 

  

 
 

  

 
 
 
 
 
 
Note:

 

The signal strength between the transmitter and the receiver decreases as the distance 

increases. Where there is a line of sight connection, the range is approximately 30m in corridors 

and 100 m in large workshops or halls. The range can be increased with an 

0

2

LINE 

repeater

Respect a minimum range of 10 cm between transmitter and receiver. 

 

 

 

 

4.1 Safety instructions 

 

The installation and initial use must only be performed by authorised qualified electricians. The 
electrical installation must be placed off-load before connection it to the mains (230V~/50Hz). 
Conform to the legislation and standards in force in the country of use. 
 

4.2 Installation 

 

 

This product is designed for indoor use. It is maintenance free.

 

  This  product  is  intended  for  installation  only  on  horizontal  DIN  rail,  in  an  electrical  panel 

(mounted on a vertical wall) with compulsory installation of a plastron which will be connected 
to the ground of the installation if it is metallic. 

  For compliance with the standard reference, height of the plastron (compared to the above 

DIN rail) must not exceed 48 mm with a minimum thickness of 1 mm. 

  NEVER  install  the  receiver  in  a  metal  casing  or  in  the  immediate  vicinity  of  large  metallic 

objects. 

  Installation on the ground or close to the ground is not recommended. Thank you to refer to 

the installation standards of each country. 

  Protect the supply line with a circuit breaker 

6A curve C

 adapted to the installation. 

 
Connection principle diagram: 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

4.3 Description of the connection 

 

-  Description of the 4 channels receiver connection: 

 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

4.4 Initial use 

 

  Connect power to the electrical installation after it has been installed. 

  Program the transmitter on the receiver (see § 5). 

 

 
 
 
 
 
 
 
 

 1. General 

 2. Safety 

   

 3. Technical characteristics 

Degree of protection 

 

 

IP20 with plastron

 

Range in buildings

 

 

Transmission frequency band

 

868.0 MHZ to 868.6 MHZ

 

Power supply

 

 

110 - 230V     

-1-

 / 50 Hz

 

Ambient temperature

 

 

from -10°C to +45°C

 

Storage temperature

 

 

from -20°C to +80°C

 

Terminal capacity

 

 

1x1,5

2

 to 2,5

2

 max rigid

 

 

General characteristics

 

Output (zero potential)

 

-2-

 

4 contacts micro distance (µ) opening 
contacts, I

min

=100mA

 

 

max µ4x1.5A/4x345VA resistive (cos 

φ

=1) 

       LED: 4x130W 
       Compact fluorescent: 4x130W 
       Halogen: 4x345W 
       Inductive: 4x300W (cos 

φ

= 0,4 à 0,6) 

Installation altitude

 

 

2000m max.

 

 4. Installation and initial use 

7mm 

WARNI

230V     

Installation and operating manual 
Modular 4 channels switch receiver for LED 
lighting 

 

 

 

Ref. 

10020110

 

EN

Ambient humidity

 

 

from 0 to 75%hr (without condensation)

 

Category receiver

 

 

Power measurement accuracy

 

2% +/- 1 digits 

-3-

 

Number of modules

 

1 module of 17.5 mm

 

Mounting type

 

DIN rail mounting

 

Consumed power

 

< 0.35 W 

-4-

 

 

 

 

 

     

 

       

   

       

 

       

Masonry

 

 

20m, through 3 walls at most

 

 

Reinforced concrete

 

 

10m, through 1 wall/ceiling at most

 

 

Plasterboard / wood

 

 

30m, through 5 walls at most

 

 

Schematic diagram of electrical 
connection to lighting loads. 
They can be replaced by other 
types of loads (see table §3).

 

Transmit power

 

+10 dBm

 

Содержание 02LINE 10020110

Страница 1: ...une utilisation conforme à sa destination Toute intervention ou modification par l utilisateur est interdite Ne pas l utiliser en liaison avec d autres appareils dont le fonctionnement pourrait mettre en danger les personnes les animaux ou les biens 1 La tension de sortie du récepteur 4 canaux est la même que la tension d alimentation 2 Nous consulter pour d autres types de charges 3 Pour des puis...

Страница 2: ...tuator Measurement Response contenant les données de consommation 5 3 2 Remise à zéro des données de consommation Mettre l appareil hors tension Maintenir enfoncé le bouton CLR puis mettre sous tension l appareil Une fois la LED 1 orange fixe attendre le passage de la LED 1 en rouge 5s puis relâcher le bouton CLR Appuyer sur le bouton LRN environ 1s pour remettre à zéro les valeurs enregistrées du...

Страница 3: ...ur du seuil de détection n est pas paramétrable valeur usine 7 1 Installation nouvelle ou existante Vérifier le coupe circuit l alimentation électrique ainsi que la charge connectée au récepteur associé à ce capteur électriciens professionnels Vérifier la charge connectée et les câbles de connexion électriciens professionnels Si le récepteur fonctionne à une distance plus courte par rapport au cap...

Страница 4: ... repairs or modifications by the user are forbidden Do not use with other devices the operation of which could endanger people animals or property 1 The output voltage of the 4 channels receiver is the same as the supply voltage 2 Consult us for other types of charges 3 For powers greater than 10W 4 Power consumed without activation of the relays Note The signal strength between the transmitter an...

Страница 5: ...ment Response frame containing the consumption data 5 3 2 Reset consumption data Switch off the device Hold down the CLR button then switch on the device Once the orange LED 1 is fixed wait for the LED 1 to go red 5s then release the CLR button Press the LRN button for about 1s to reset the recorded values of the receiver to zero the red LED goes out to confirm the erasure of the data 5 For more d...

Страница 6: ...ion threshold is not configurable factory value 7 1 New or existing installation Check the circuit breaker the electrical supply and the load connected to the receiver associated with this sensor qualified electricians Check the connected load and the connecting cables qualified electricians If the receiver functions at a shorter distance relative to the sensor it is subject to interference or use...

Отзывы: