![TREVIDEA G3FERRARI DOLCE ESTATE 9000 Скачать руководство пользователя страница 18](http://html1.mh-extra.com/html/trevidea/g3ferrari-dolce-estate-9000/g3ferrari-dolce-estate-9000_user-manual_1159192018.webp)
17
3. VENTILATION MODE (FAN ONLY)
In this mode, the fan speed can be adjusted. The temperature cannot be adjusted.
4. TIMER
a. When conditioner is turned off, press “TIMER” to set a time to turn on the air conditioner. Press UP (+) or
DOWN (-) to set the time, and press “TIMER” again to confirm it. Wait 5 seconds without pressing any key.
b. When conditioner is turned on, press “TIMER” to set a time to turn off the air conditioner. Press UP (+) or
DOWN (-) to set the time, and press “TIMER” again to confirm it. Wait 5 seconds without pressing any key.
WATER DRAINAGE
Cooling
This appliance automatically vaporises condensate in the cooling mode. Ensure
that when the unit is operating in cooling and heating mode, the rubber caps
closing the drainage holes on the rear of the appliance are properly positioned.
When the air conditioner operates in cooling mode, there is no need for
continuous condensate drainage; only in specific weather conditions with very
high air humidity levels may water deposit inside the unit. When the internal
container is full, the display visualises message “
FL
” and the appliance stops functioning.
To empty the container, switch the air conditioner off and unplug it. Remove the cap form the lower drainage
hole (9) and direct it over a normal drain. Ensure that tube is not twisted or bent. The tube must slope
downwards. Re-close drainage hole with the cap and resume use of air conditioner.
Dehumidification
WARNING!
When using the air conditioner in
dehumidification mode, always
arrange for
continuous
drainage
, so as to maximise dehumidification efficiency.
Connect an end of a PVC pipe (not included) to upper drain hole (14) and place the other end on a container.
AIR FILTER
Unplug unit from the electrical outlet before pulling out the filter.
The air filters (Upper filter 16 and lower filter 8) must be checked at least once every two weeks of use.
Operating the appliance with dirty or clogged filters will decrease the air conditioner's efficiency and may
cause serious problems. Use a vacuum cleaner to remove the dust from the filters. Should this not suffice,
wash the filter with lukewarm water and some neutral detergent (if necessary), then rinse it thoroughly in cold
water and leave it to dry in air before putting it back in place. Once the filter has been replaced, close the
grille and resume use of the air conditioner.
When you do not expect to use the air conditioner for a long time, clean the filters before storing it away.
CLEANING
Unplug unit from the electrical power outlet before starting any cleaning operation
.
To clean unit, use non-abrasive sponges or soft slightly damp cloths. Don’t use thinner or cleaning agents as
they may damage unit seriously. Do not use flammable cleaning agents or sprays on any part of the product.
TECHNICAL FEATURES
Power supply: AC 230V
~
50Hz. Power: 1010W
Cooling capacity 9000 BTU/h – 2.64 kWh
Removed humidity in dehumidify function: 24L/day
Sound pressure level: 52 dB(A) (low speed), 55 dB(A) (high speed)
Energy efficiency class: A (EER: 2.64)
Functions: cooling, dehumidify, fan, timer 24h and sleep function
Accessories: tube (Ø 15cm, L 160cm), window adaptor (93-126cm)
Dimensions (mm): H 698, L 354, P 338– Weight 22 Kg
Min/max operating limits (internal temperature)
Cooling: 16 °C
/
35 °C
Dehumidification: 17 °C
/
35 °C