MENUS AND PARAMETERS (cont’d)

ADVANCED Setpoints Menu 

Press and hold the

BACK

button to enter the 

Advanced Setpoints 

menu.

ABR.

ON-BOARD 

DISPLAY

DASHBOARD 

DISPLAY

FULL NAME

MIN

MAX

DEFAULT

DESCRIPTION

FoC

FOC

FANS ON COMP

Fans on with Compres-

sor

Manage fans in OFF, then ON in refrigeration

PEr

PEr

FANS PERMANENT

Permanent Fan

Fans on permanently during refrigeration cycle - RECOMMENDED

CYC

CYC

CYCLE

Cycle

Cycle (Managed) manage fans during refrig cycle. Not Recom-

mended for Equipment Equipped with 2  Speed EC Motors (Smart-

Speed) or Variable Speed EC Motors

t24

t24

TITLE 24

Title 24

Cycle fans based on compliance with California Title 24 regula-

tions  (Available only with Equipment Equipped with Variable 

Speed EC Motors)

Stt

Stt

SUPERHEAT

Superheat

5.0 °F

30.0 °F

8.0 °F

Target superheat value. Not available on Basic Display

LPt

LPt

LOW PRESSURE 

CUT OUT TIME

Low Pressure Cut Out 

Time

0 min

15 min

0 min

Only applies when non-mechanical valve selected; 0=Disabled

LPC

LPC

LOW PRESSURE 

CUT OUT

Low Pressure Cut Out

-5.0 psig 138.0 psig

8.0 psig

Displays when LOW PRESSURE CUTOUT TIME (LPt) is 

greater than zero. And,only applies if non-mechanical valve is 

selected

LPd

LPd

PRESS DIFF FOR 

LPCO

Pressure  Differential 

for LPCO

1.0 psig 20.0 psig

15.0 psig

Displays when LOW PRESSURE CUTOUT TIME (LPt) is 

greater than zero. And,only applies if non-mechanical valve is 

selected

Att

Att

LPCO ATTEMPTS

CONTACT FACTORY

1

5

5

If LPt greater then 0: Advanced topic. CONTACT FACTORY

rnt

rnt

COMP RUN TIME 

Compressor Run Time

0 hrs

24 hrs

6 hrs

When rnt selected, number of hours of cooling before starting 

defrost

Htn

Htn

ELECTRIC DE-

FROST MODE

Electric Defrost Mode

N/A

N/A

Permanent for 

AD / 

Pulse for ED

If DEFROST TYPE = ELE:  Whether to leave the defrost relay 

energized during the defrost cycle or to utilize advanced 

defrost algorithm. PUL = Pulse, Prn = Permanent

HAo

HAo

HIGH TEMP 

ALARM OFFSET

High Temp Alarm 

Offset

0 °F

99.9 °F

10.0 °F

The number of degrees above  ROOM TEMP  for a HIGH TEMP 

ALARM condition.

HAd

HAd

HIGH TEMP 

ALARM DELAY

High Temp Alarm Delay

0 min

120 min

60 min

Minutes the room temperature must remain above ROOM TEMP 

+ HIGH TEMP ALARM OFFSET before issuing a HIGH TEMP 

ALARM

LAo

LAo

LOW TEMP 

ALARM OFFSET

Low Temp Alarm Offset

0 °F

20.0 °F

4.0 °F

The number of degrees below  ROOM TEMP  for a LOW TEMP 

ALARM condition.

LAd

LAd

LOW TEMP 

ALARM DELAY

Low Temp Alarm Delay

0 min

30 min

10 min

Minutes the room temp must remain below ROOM TEMP-LOW-

TEMP ALARM OFFSET before issuing a LOW TEMP ALARM

dAd

dAd

DOOR ALARM 

DELAY

Door Alarm Delay

0 min

180 min

30 min

If AU IN (1, 2 and/or 3) MODE =  dor The amount of time, in 

minutes, before an alarm condition is initiated, if door is open 

& room temperature is 5 degrees above ROOM TEMP + AIR 

TEMP DIFF

AU1

AU1

AUX IN 1 MODE

Aux Input 1 mode

N/A

N/A

Coil Temp See Auxiliary Input Modes table

A1A

A1A

AUX IN 1 STATE

Aux Input 1 state

N/A

N/A

Closed

oPn= active if input is an open / CLo=active if input is shorted

AU2

AU2

AUX IN 2 MODE

Aux Input 2 mode

N/A

N/A

Disabled

See Auxiliary Input Modes table

A2A

A2A

AUX IN 2 STATE

Aux Input 2 state

N/A

N/A

Closed

oPn= active if input is an open / CLo=active if input is shorted

AU3

AU3

AUX IN 3 MODE

Aux Input 3 mode

N/A

N/A

Sys Off

See Auxiliary Input Modes table

A3A

A3A

AUX IN 3 STATE

Aux Input 3 state

N/A

N/A

Closed

oPn= active if input is an open / CLo=active if input is shorted

tS2

tS2

ROOM TEMP

2nd room temp SP

-50.0 °F

90.0 °F

-50.0 °F

If AU IN (1, 2 and/or 3) MODE = (t2n) 2ND ROOM TEMP: This 

value becomes the ROOM TEMP setpoint when the digital input 

is active 

10t

10t

0 TO 10 VDC MODE

CONTACT FACTORY

-

-

Alarm Relay (ALr) Alarm relay. (FSd) Evap Fan Speed Control. (dAL) Door 

alarm relay.

tEt

tEt

MULTI EVAP MODE

CONTACT FACTORY

-

-

Off

Mode for Lead/Lag operation. (oFF) Off. (LGC) Redundant 

Cool. (LGF) Redundant Off. (ALt) Alternate.

PAd

PAd

PAIRED DEFROST 

MODE

CONTACT FACTORY

-

-

Off

Select operation when lead/lag pair controller goes into 

defrost. (oFF) Off. (AUt) Auto.

LLt

LLt

LEAD/LAG TIME

CONTACT FACTORY

1 hour 168 hours

12 hours

Time to toggle between lead/lag

Unt

Unt

TEMP UNITS

temperature units

N/A

N/A

Fahrenheit Units for temperature’s display in °F or °C; FAH = Fahrenheit, 

CEL = Celsius

EdF

EdF

EXTREME TEMP 

DIFF

Extreme Temp Diff.

0

F

99.9 °F

20.0 °F

ADVANCED TOPIC: Call factory for assistance 

CLA

CLA

CLEAR ALARMS

Clear Alarms

N/A

N/A

Press and hold to clear all active alarms

PAS

PAS

WEB PASSWORD 

RESET

Web password reset

N/A

N/A

Press and hold to reset the web password to the factory 

default  

PAr

PAr

PAIR L/L

Pair controllers

-

-

-

Press and hold ENTER until red LED blinks. 

(PAS) successful pairing. (FAi) pairing failed. 

Only two controllers can be present on network.

UnP

UnP

UNPAIR L/L

Unpair controllers

-

-

-

Press and hold ENTER until red LED blinks. 

(PAS) successful unpairing. (FAi) unpairing failed.

bnd

bnd

BOND

Bond controllers

-

-

-

Press and hold ENTER until red LED blinks. 

(PAS) successful bond. (FAi) bond failed. Only two controllers 

can be present on network to bond from display.

Unb

Unb

UNBOND

Unbond controllers

Press and hold ENTER until red LED blinks. Controllers will un-

bond and restart. Only works if bonded to one other controller.

SA

SA

SMART ACCESS

Smart Access

N/A

N/A

Disabled

Turn Smart Access on or off: EnA to enable smart access / 

diS to disable Smart Access (CONTACT FACTORY)

dHC

dHC

DHCP

DHCP Mode

N/A

N/A

Disabled

Turn DHCP mode on or off: EnA to enable DHCP mode / diS to 

disable DHCP mode

T30-ESP-OM--1

11/09/20

- 4 -

Содержание ESP+

Страница 1: ...Support Resources 2 3 3 6 7 8 9 10 11 12 14 15 17 BACK Intuitive Evaporator Control Technology Bulletin T30 ESP OM 2 1 Part 1107522 OPERATING INSTRUCTIONS PRODUCT SUPPORT web www t rp com esp email e...

Страница 2: ...default view Manual Valve Control Press and hold the BACK button arrow to put the EEV in Manual Control mode and arrows will control the valve opening ENTER will advance to the next digit and BACK wi...

Страница 3: ...ULT DESCRIPTION tS tS ROOM TEMP Room Temp Setpoint 50 0 F 90 0 F 10 F or 35 F Walk in freezer 10 F or cooler 35 F room temp to be main tained rFG rF REFRIGERANT Refrigerant N A N A R 404A Type of refr...

Страница 4: ...or The amount of time in minutes before an alarm condition is initiated if door is open room temperature is 5 degrees above ROOM TEMP AIR TEMP DIFF AU1 AU1 AUX IN 1 MODE Aux Input 1 mode N A N A Coil...

Страница 5: ...vap Defrost Synchronized or Independent Synchronized Synchronized synchronize bonded controller in defrost mode Inde pendent bonded controllers defrost independently MULTI EVAP SENSOR Multi Evap Senso...

Страница 6: ...umber of times to maintain suction pressure LPA LPA LOW PRESSURE Low Pressure Alarm Suction pressure dropped below expected point excessive number of times PrF PrF N A Process Failure Basic Display is...

Страница 7: ...List sticker on the inside of the access panel of the evaporator 5 On a computer connected to the same network as your ESP controller open any browser Chrome Firefox Edge etc 6 Enter the ESP controll...

Страница 8: ...iP1 5 Record the four IP iP1 iP2 iP3 iP4 values a Use the and arrows to find iP1 iP1 c Press and release the ENTER button to display the current setting d Record this number e Press the BACK button f...

Страница 9: ...If using a mobile device open the WIFI network settings to see available networks There are 2 wireless networks available a KE2WIFIST wireless network is Open and no password is required b KE2LDA wir...

Страница 10: ...Select submit or press enter on your keyboard 7 Click Discover The IP addresses of the available controllers will populate Click OK if prompted by browser to confirm 8 Type 1 in the Bond State area of...

Страница 11: ...method is used to control the temperature 16 Click Save to save the settings 17 The second controller and subsequent controllers must be configured to match the Multi settings of the first controller...

Страница 12: ...SAMPLE WIRING DIAGRAM 208 230 1 60 AIR DEFROST MODELS w SAMPLE ONLY Refer to Product Data and Installation for details specific to your unit SAM PLE O N LY T30 ESP OM 1 11 09 20 12...

Страница 13: ...SAMPLE WIRING DIAGRAM 208 230 1 60 ELECTRIC DEFROST MODELS w SAMPLE ONLY Refer to Product Data and Installation for details specific to your unit SAM PLE O N LY T30 ESP OM 1 11 09 20 13...

Страница 14: ...CLo Closed Setpoint Option for Aux Input State A1A A2A A3A setpoints Input will be Active when it reads a closed circuit CLt CLt Coil Temp Variables Coil temperature TCoil Sensor as measured by the co...

Страница 15: ...drops on the walk in s surfaces Fir Fir Firmware Version Variables Current version of the firmware on the controller FoC FoC Fans on with Compressor Setpoint Option under Refrig Fan Type rFt setpoint...

Страница 16: ...by the Auxiliary Input SA SA KE2 Smart Access Setpoint Turn KE2 Smart Access on or off EnA enable KE2 Smart Access diS disable KE2 Smart Access SAt SAt Saturation Temp Variables Saturation temperature...

Страница 17: ...NOTES T30 ESP OM 1 11 09 20 17...

Страница 18: ...NOTES T30 ESP OM 1 11 09 20 18...

Страница 19: ...PRODUCT SUPPORT RESOURCES Visit www t rp com esp for product information manuals FAQ and more T30 ESP OM 1 11 09 20 19...

Страница 20: ...com call 1 844 893 3222 x501 email shipping t rp com call 1 844 893 3222 x503 web www t rp com warranty email warranty t rp com call 1 844 893 3222 x507 Due to the manufacturer s policy of continuous...

Отзывы: