TRENDnet TEG-7080ES Скачать руководство пользователя страница 33

 

 

 

 

 

 

 

 

 

 

© Copyright 2018 TRENDnet. All Rights Reserved. 

 

 

 

 

TRENDnet User’s Guide

 

Limited Warranty 

31

 

Limited Warranty 

TRENDnet warrants only to the original purchaser of this product from a TRENDnet 

authorized reseller or distributor that this product will be free from defects in material 

and workmanship under normal use and service. This limited warranty is non-

transferable and does not apply to any purchaser who bought the product from a 

reseller or distributor not authorized by TRENDnet, including but not limited to 

purchases from Internet auction sites. 

 

Limited Warranty

 

TRENDnet warrants its products against defects in material and workmanship, under 

normal use and service. Specific warranty periods are listed on each of the respective 

product pages on the TRENDnet website.  

 

AC/DC Power Adapter, Cooling Fan, and Power Supply carry a one-year 

warranty. 

Limited Lifetime Warranty 

TRENDnet offers a limited lifetime warranty for all of its metal-enclosed network 
switches that have been purchased in the United States/Canada on or after 1/1/2015. 

 

 

Cooling fan and internal power supply carry a one-year warranty 

 

To obtain an RMA, the ORIGINAL PURCHASER must show Proof of Purchase and return 
the unit to the address provided. The customer is responsible for any shipping-related 
costs that may occur. Replacement goods will be shipped back to the customer at 

TRENDnet’s expense.

 

 

Upon receiving the RMA unit, TRENDnet may repair the unit using refurbished parts. In 
the event that the RMA unit needs to be replaced, TRENDnet may replace it with a 
refurbished product of the same or comparable model. 

 

In the event that, after evaluation, TRENDnet cannot replace the defective product or 
there is no comparable model available, we will refund the depreciated value of the 
product. 

 

If a product does not operate as warranted during the applicable warranty period, 

TRENDnet shall reserve the right, at its expense, to repair or replace the defective 

product or part and deliver an equivalent product or part to the customer. The 

repair/replacement unit's warranty continues from the original date of purchase. All 

products that are replaced become the property of TRENDnet. Replacement products 

may be new or reconditioned. TRENDnet does not issue refunds or credit. Please 

contact the point-of-purchase for their return policies. 

 

TRENDnet shall not be responsible for any software, firmware, information, or memory 

data of customer contained in, stored on, or integrated with any products returned to 

TRENDnet pursuant to any warranty. 

 

There are no user serviceable parts inside the product. Do not remove or attempt to 

service the product by any unauthorized service center. This warranty is voided if (i) the 

product has been modified or repaired by any unauthorized service center, (ii) the 

product was subject to accident, abuse, or improper use, or (iii) the product was subject 

to conditions more severe than those specified in the manual. 

 

Warranty service may be obtained by contacting TRENDnet within the applicable 

warranty period and providing a copy of the dated proof of the purchase. Upon proper 

submission of required documentation, a Return Material Authorization (RMA) number 

will be issued. An RMA number is required in order to initiate warranty service support 

for all TRENDnet products. Products that are sent to TRENDnet for RMA service must 

have the RMA number marked on the outside of return packages and sent to TRENDnet 

prepaid, insured and packaged appropriately for safe shipment. International customers 

Содержание TEG-7080ES

Страница 1: ...Copyright 2018 TRENDnet All Rights Reserved TRENDnet User s Guide Cover Page 1...

Страница 2: ...l Interface 12 Configure Physical Interfaces 12 Bridge 13 Configure Trunking 13 Configure port mirror settings 14 Enable loopback detection 15 Configure IGMP Snooping Settings 15 Configure Storm Contr...

Страница 3: ...interface offers features for traffic control troubleshooting access controls and monitoring TRENDnet s TEG 7080ES allows for simple network integration into your SMB network High Speed 10GBASE T Off...

Страница 4: ...ld to turn LED lights on or off LED Indicators Indicator for device Power and System status 10GBASE T Ethernet Ports 1 8 Connect network devices or servers Console Port Use the included RJ 45 to RS 23...

Страница 5: ...Amber When the Link Act LED is on the link established is operating at 5Gbps speeds On Green When the Link Act LED is on the link established is operating at 10Gbps speeds Off When the Link Act LED l...

Страница 6: ...tion Install the Switch on a sturdy level surface that can support its weight or in an EIA standard size equipment rack For information on rack installation see the next section Rack Mounting When ins...

Страница 7: ...Password and then click Login By default User Name admin Password admin Note User name and password are case sensitive 6 Click System and then click IPv4 Setup 7 Configure the switch IP address settin...

Страница 8: ...n the front panel of your switch to ensure the physical cable connection from your computer or device You can use either the 10GBASE T Ethernet ports connections as network uplinks Note If you encount...

Страница 9: ...er Name and Password are case sensitive System Info View your switch status information System Info You may want to check the general system information of your switch such as firmware version and sys...

Страница 10: ...switch This information helps in identifying each specific switch among other switches in the same local area network Entering this information is optional 1 Log into your switch management page see A...

Страница 11: ...gs When you have completed making changes click Apply to save the settings System MAC Address Displays the switch MAC address information System IP Address Enter the new switch IP address e g 192 168...

Страница 12: ...r switch management page on page 7 2 Click on System and click on IPv6 System Settings 3 Review the settings When you have completed making changes click Apply to save the settings IPv6 State The IPv6...

Страница 13: ...Single User Access box and click Apply Access to the switch management page will automatically timeout after 5 minutes 4 Click Apply to save configuration changes to the NV RAM to ensure that if the s...

Страница 14: ...and receive Ethernet frames Mode This parameter indicates the speed and duplex mode settings for the port You can use this parameter to set the speed and duplex mode of a port The possible settings ar...

Страница 15: ...ely limited the effective bandwidth of your network 1 Log into your switch management page see Access your switch management page on page 7 2 Click on Bridge click on Trunk Config and click on Trunkin...

Страница 16: ...r monitoring and troubleshooting purposes 1 Log into your switch management page see Access your switch management page on page 7 2 Click on Bridge and click on Mirroring 3 Review the settings Click A...

Страница 17: ...to save configuration changes to the NV RAM to ensure that if the switch is rebooted or power cycled the configuration changes will still be applied Configure IGMP Snooping Settings Bridge IGMP Snoopi...

Страница 18: ...configuration changes to the NV RAM to ensure that if the switch is rebooted or power cycled the configuration changes will still be applied Set Ingress Egress Rate Limiting Bridge Bandwidth Control R...

Страница 19: ...mation within a frame is examined when it is received to determine if the frame is qualified as a member of a specific tagged VLAN If it is it is eligible to be switched to other member ports of the s...

Страница 20: ...gn VLAN IDs for untagged packets through 802 1q VLAN 4 Click Apply to save configuration changes to the NV RAM to ensure that if the switch is rebooted or power cycled the configuration changes will s...

Страница 21: ...izing traffic Set IEEE 802 1P settings Bridge QoS IEEE 802 1P QoS 1 Log into your switch management page see Access your switch management page on page 7 2 Click on Bridge and click on QoS 3 By defaul...

Страница 22: ...Click on Bridge and select QoS 3 Change QoS Mode Setting to Port Based QoS 3 For each port select a Queue in the Priority Settings Click Apply to save the settings 5 Change the Scheduling Method Sett...

Страница 23: ...using the link http www trendnet com downloads In addition it is also important to verify if the latest firmware version is newer than the one your switch is currently running To identify the firmware...

Страница 24: ...ng from a backed up switch configuration file The configuration will be backed up or restored only to the currently used image Backup Restore via HTTP Settings To backup your switch configuration 1 Lo...

Страница 25: ...wire within the cable o Short Two wires are shorted together within the cable Clear The Clear button can be used to clear the Cable Diagnostic test results Enable IEEE 802 3az Power Saving Mode Tools...

Страница 26: ...actory defaults if you are encountering difficulties with your switch and have attempted all other troubleshooting Before you reset your switch to defaults if possible you should backup your switch co...

Страница 27: ...t Logout Technical Specifications Standards IEEE 802 1p IEEE 802 1Q IEEE 802 3u IEEE 802 3x IEEE 802 3ab IEEE 802 3ad IEEE 802 3az IEEE 802 3an IEEE 802 3bz Device Interface 8 x 10GBASE T 10Gbps 5Gbps...

Страница 28: ...ed Host IP Access List Minimum Cable Requirements 10GBASE T 10 Gbps Cat 6 twisted pair 55m 180 ft max Cat 6a or Cat 7 twisted pair 100m 328 ft max NBASE T 5 Gbps Cat 6 twisted pair 100m 328 ft max NBA...

Страница 29: ...on icon and click Properties c Click Internet Protocol Version TCP IPv4 and then click Properties d Then click Use the following IP address and make sure to assign your network adapter an IP address i...

Страница 30: ...nd your IP address settings displayed Note If you are experiencing difficulties please contact your computer or operating system manufacturer for assistance How to configure your network settings to u...

Страница 31: ...tic IP address Then click the Apply button f Restart your computer Note If you are experiencing difficulties please contact your computer or operating system manufacturer for assistance How to find yo...

Страница 32: ...ved by the party responsible for compliance could void the user s authority to operate this equipment This device complies with Part 15 of the FCC Rules Operation is subject to the following two condi...

Страница 33: ...ace the defective product or there is no comparable model available we will refund the depreciated value of the product If a product does not operate as warranted during the applicable warranty period...

Страница 34: ...E NEGLECT IMPROPER INSTALLATION OR TESTING UNAUTHORIZED ATTEMPTS TO REPAIR OR MODIFY OR ANY OTHER CAUSE BEYOND THE RANGE OF THE INTENDED USE OR BY ACCIDENT FIRE LIGHTNING OR OTHER HAZARD LIMITATION OF...

Страница 35: ......

Отзывы: