background image

 

Operating manual OPTIMAL Control Eco (2112) 

 

  

 

 

12 

 

 

 

 
 
 
 

 

Breddningsving
en monteras på 
insidan av 
maskinen 
 
 

 

 

Features and switches on the handset  

 

Description of the function of the handset 

 

 

Name 

Function/ 
description 

Switch 

Requirements / 
Comments

 

Type 

Direction 

Placer.  Symbol 

Spreader 
activation 

Start and stop of 
spreader 

Switch  
(on LED) 

Up/down 

S T A R T

S T O P

 

Starts and stops the 
signal to the hydraulic 
motors and thus the 
auger and spreader 
disc rotation. 
LED lights up when 
activated.

 

Spread 
amount

 

Setting of spread 
amount 

Switch 

Up/down 

 

-

G R / M ²

+

 

Adjustment step by 
spreading quantity

  

( = 5 %) 

Spreading 
width 

Setting of spreading 
width 

Switch 

Up/down 

+

M

-

 

Adjustment step by 
spreading width

  

( = 5 %) 

Adjustment 
buttons

 

Change of the input 
values and Info in 
the standard display 
with menu shifts

 

Push-
button

 

 

 

Enter 

Switch to sub-
menus and approval 
of an input

 

Push-
button 

MENU

 

 

Esc 

"Go" back a step in 
menus and undo 
input.

 

Push-
button 

ESC

 

 

 
 
 

 

 

 

 

 

 

 

 

 

Содержание OPTIMAL Control Eco

Страница 1: ...nce OPTIMAL Control Eco Supplement to the sand spreader manual TREJON F RS LJNINGS AB F retagsv gen 9 SE 911 35 V NN SBY SWEDEN Tel 46 0 935 39 900 Fax 46 0 935 39 919 Webb trejon se Edition 2016 09 N...

Страница 2: ...handset OPTIMAL Control Eco 9 Generally 9 Display 10 Description of menu set user 11 Concluding remarks 11 Features and switches on the handset 12 Outputs 13 Other technical specifications 13 Functio...

Страница 3: ...IS ENDANGERED A word of advice Pay special attention to the words WARNING CAUTION and NOTE in the safety instructions The words have been chosen from of the following WARNING This safety sign is used...

Страница 4: ...ou will ensure the long and effective use of the equipment We have produced this manual for you to get a good understanding of the functioning of the equipment and what safety and maintenance instruct...

Страница 5: ...ironmentally friendly way Check if delivery is complete with help from machine order packing list Check that the machine is lubricated see section Service and maintenance Check that chain has right te...

Страница 6: ...al to give the user the opportunity to use the functions in the control fully The control is designed for use in accordance with the above described application Any other use of control is associated...

Страница 7: ...2 7 Breddningsving en monteras p insidan av maskinen Mounting instruction This pictures will show the correctmounting to the spreader Dissmount the steelplate for the hose clamp Bolt the new support o...

Страница 8: ...g manual OPTIMAL Control Eco 2112 8 Breddningsving en monteras p insidan av maskinen Mount the contact to the support Mount the two Hirschman contacts to the coils for the valves with rubber seals and...

Страница 9: ...itches Generally This document contains basic description of the features at steering Optimal Control Eco Superior machine and product description During normal operation of the machine set the desire...

Страница 10: ...is displayed Information Unit Symbol Comments 1 Spreading width PWM 0 100 5 increments 2 Spread amount PWM 0 100 5 increments 3 Menu messages for easy maneuvering of the setting See the function desc...

Страница 11: ...ept the Enter button depressed 2 seconds and when a value is flashing it can be changed The value can then be changed with the Up Arrow and Arrow Down Press Enter to accept or Esc to cancel the entry...

Страница 12: ...and stops the signal to the hydraulic motors and thus the auger and spreader disc rotation LED lights up when activated Spread amount Setting of spread amount Switch Up down G R M Adjustment step by s...

Страница 13: ...ength 2 m with BOSCH contact The cable from the handset to the 7 pin trailer plug is 7 0 75 mm2 length 6 m Power supply 12 V DC min 9 V DC and max 28 V DC Fuse T16 Amp 250 Volt Max load Long term 7 0...

Страница 14: ...onditions Setting the spreading width can not be undertaken when the menu setting is enabled When the upper lower limit of the spread rate is reached a sound alarm is given single beep for each additi...

Страница 15: ...ay back Light on OFF on OFF Appendix 2 Cable connection 1 2 3 4 5 6 7 1 2 3 4 5 6 7 Master ventil MOSFET Master ventil Spredetallerken MOSFET Spredetallerken Ingen forb Ingen forb Dos Snegl MOSFET Dos...

Страница 16: ...already delivered Pictures in the manual do not necessarily show the equipment as delivered Technical data weights and measures are without obligation Reservation for faults 2016 Trejon AB Sweden Cop...