9-4 Nozzle Detect
PROBLEM
POSSIBLE CAUSE
CORRECTIVE ACTION
1. No LED lights on sensor.
1. Loose connection of power cable.
2. Broken cable.
3. Damaged sensor.
1. Check that the connection is secure.
2. Replace sensor.
3. Replace sensor.
2. No signal from sensor but
power LED is illuminated.
1. Nozzle not close enough to sensor.
1. Confirm that robot position is at the correct distance
from the sensor (see section 4-7 Setting Up Nozzle
Detect on page 18).
3. Both LEDs are always
illuminated.
1. Metallic debris on sensor.
2. Nozzle is too close to sensor.
1. Wipe the face of the sensor clean with a rag.
2. Confirm that robot position is at the correct distance
from the sensor (see section 4-7 Setting Up Nozzle
Detect on page 18).
OM-TT3-1.4