Safety 

 
 
 

Representations and symbols 

 

Important instructions, which involve safety, are highlighted with the appropriate mark: 

 
 
 
 

 

Safety recommendations 
 

When using the weighing equipment in surroundings with increased safety requirements, 
the corresponding regulations must be observed. 
 
The weighing scale may only be used with the power adapter supplied. 
Before connecting the power adapter to the scale, the user must ensure that the 
operating voltage stated on the power adapter is compliant with the mains voltage. 
If not, please contact Customer Service at the address above. 
 
If the power adapter or its cable is damaged, the weighing scale must immediately be 
disconnected from the electricity supply (pull out the power adapter).  
 
If there should be any reason to believe that it is no longer safe to operate the scale, it 
should be immediately unplugged from the electricity supply (pull out power adapter) and 
secured against inadvertent operation. 

 

In carrying out maintenance work, it is essential to follow the recommendations set out in 
maintenance and servicing. 
 
The weighing scale must not be operated in an area subject to explosion risks. 
 
Care must be taken when weighing liquids to ensure that no liquid is spilled into the 
inside of the scale or into connections on the rear of the equipment or the power adapter. 
If liquid is spilled on the scale, it must immediately be unplugged from the main electricity 
supply (pull out power adapter). 
 
The weighing scale may be operated after it has first been inspected by a service 
technician. 
 
These operating instructions must be read by each user and should be easily accessible 
at the workplace at all times. 

 

 
 
 

 

Содержание HRB 203

Страница 1: ...Professional Weighing Equipment HRB Series intelligent weighing scale HIGH RESOLUTION BALANCE WITH COUNTING FUNCTION HRB 103 HRB 203 HRB 303 HRB 1002 HRB 602 Operation Manual...

Страница 2: ...Service 4 Introduction 5 Safety 6 Weight Scale 7 Functions 8 Features 9 Application Conformity 10 RS232 11 Getting Started 12 Delivery 12 Assembly Installation 13 14 Program Options 15 Parameter Sett...

Страница 3: ...his declaration refers conforms to the following standards Electronic scale HRB High Resolution Balances USA model UK Europe model HRB 103 HRB 203 HRB 303 HRB 1002 HRB 602 Mark applied EU Directive St...

Страница 4: ...son Court Rohnert Park CA 94928 USA Tel 707 542 2185 FAX 707 542 3285 http lwmeasurements com EUROPE LW Measurements Europe Ltd Chalkwell Park House 700 London Road Westcliff on Sea Essex SS0 9HQ Unit...

Страница 5: ...ese operating instructions in their entirety so that you can make optimum use of the full potential and the diverse possibilities of the weighing scale in your daily work These operating instructions...

Страница 6: ...adapter If there should be any reason to believe that it is no longer safe to operate the scale it should be immediately unplugged from the electricity supply pull out power adapter and secured again...

Страница 7: ...2 12 02 2016 7 Weight Scale Construction Functions The weighing scale consists of the following parts Weight scale body The scale pan Glass Draft Shield The adapters Operating manual Glass Draft Shie...

Страница 8: ...HRB 203 200g 0 1g 98mm x 98mm HRB 303 300g 0 1g 98mm x 98mm HRB 1002 1000g 0 1g 135mm x 120mm HRB 602 600g 0 1g 135mm x 120 mm 2 2kg 3 1 kg Net gross weight Package 36 x 23 x 14 cm3 Standard carton 3...

Страница 9: ...el pan Stability indication Auto calibration Selectable auto back light Selectable beeper Selectable auto shut off Unit switching g ct oz tola 1 3 million internal resolution 24 bit A D processor Less...

Страница 10: ...accordance with instructions must be observed The weighing scale has been manufactured and tested in accordance with the standards and recommendations set out in the declaration of conformity The pow...

Страница 11: ...sion 57H 3AH P Polarity 2BH Positive 2DH Negative DATA 12 345 20H 20H 20H 20H 31H 32H 2EH 33H 34H 35H UNIT g 67H 20H 20H 20H 20H oz 6FH 7AH 20H 20H 20H lb 6CH 62H 20H 20H 20H dwt 64H 77H 74H 20H 20H o...

Страница 12: ...should be stored for a couple hours and kept in its box in a dry room at normal temperature so that no condensation settles on the unit when opening the box Check the scale immediately after unpackin...

Страница 13: ...the power adapter to the mains socket that the operating voltage stated on the power adapter complies with the local mains voltage If the operating voltage is not the same as the mains voltage the pow...

Страница 14: ...t be adjusted so that the air bubble is precisely in the center of the sight glass of the bubble level see Fig 3 2 Place the scale horizontally and keep the bubble inside the bubble level aligned with...

Страница 15: ...ts com for practical demonstrations of application usage Interface Settings Press On Off to turn on the scale when instrument displays Press Print the display will show b xxx BAU value Press Unit to s...

Страница 16: ...d range Press the On Off key and when shows press PCS key and then press Zero key multiple times till display shows Ovr xx press the Unit key to select factory default setting is 9d Setting Beeper Pre...

Страница 17: ...he balance is moved to a substantial distance from the original location Turn the Balance on and let it warm up for about 10 minutes then press the power key twice when the display shows press the Zer...

Страница 18: ...a soft lint free cloth moistened with a mild soap solution Never use solvents acids alkalis paint thinners scouring powders or other aggressive or corrosive chemicals for cleaning these substances can...

Страница 19: ...al box If they are not properly packed an in the original box the customer pays for shipping cost If we determine there is a factory defect we will pay for the shipping back If we determine that it is...

Отзывы: