OMNI-Test Laboratories, Inc.
Manufacturer: Travis Industries
Model: 44 Elite
Project No.: 0028WF061E
Tracking No.: 2305
Run: 1
Test Date:
Burn Rate
5.38 kg/hr dry
Average Tunnel Temperature
196 degrees Fahrenheit
Average Gas Velocity in Dilution Tunnel - vs
21.70 feet/second
Average Gas Flow Rate in Dilution Tunnel - Qsd
11819.0 dscf/hour
Average Delta p
0.093 inches H20
Total Time of Test
202 minutes
Total Sample Volume - Vm
0.000 cubic feet
32.581 cubic feet
34.640 cubic feet
9.700 cubic feet
Average Gas Meter Temperature
74 degrees Fahrenheit
79 degrees Fahrenheit
78 degrees Fahrenheit
77 degrees Fahrenheit
Total Sample Volume (Standard Conditions) - Vmstd
0.000 dscf
30.855 dscf
32.531 dscf
9.213 dscf
Total Particulates - m
n
0 mg
17.8 mg
20.6 mg
3.8 mg
Particulate Concentration (dry-standard) - C
r
/C
s
0.000000 grams/dscf
0.00058 grams/dscf
0.00063 grams/dscf
0.00041 grams/dscf
Total Particulate Emissions - E
T
0.00 grams
22.95 grams
25.20 grams
4.88 grams
Particulate Emission Rate
0.00 grams/hour
6.82 grams/hour
7.48 grams/hour
4.88 grams/hour
Emissions Factor
1.27 g/kg
1.39 g/kg
0.93 g/kg
Difference from Average Total Particulate Emissions
1.12 grams
1.12 grams
Complete Test Run
Total Particulate Emissions - E
T
24.08 grams
Particulate Emission Rate
7.15 grams/hour
Emissions Factor
1.33 grams/kg
First Hour Emissions
Total Particulate Emissions - E
T
4.88 grams
Particulate Emission Rate
4.88 grams/hour
Emissions Factor
0.93 grams/kg
7.5% of Average Total Particulate Emissions
1.81 grams
Technician Signature:_____________________________________________________
OK
OK
OK
Stove Surface
∆
T
NOT ACCEPTABLE
OK
Filter Face Velocity (47 mm)
Dryer Exit Temp < 80F
Leakage Rate
Ambient Temp (55-90
°
F)
Negative Probe Weight Eval.
OK
Pro-Rate Variation
OK
QUALITY CHECKS
FINAL AVERAGE RESULTS
FIRST HOUR FILTER (TRAIN 1)
Dual Train Comparison Results Are Acceptable
Filter Temps < 90
°
F
NOT ACCEPTABLE
Wood Heater Test Results
09/11/18
SAMPLE TRAIN 1
SAMPLE TRAIN 2
AMBIENT
Control No. P-SSAR-0003
Run 1 High_Entire test-2 minute data
34 of 158
Содержание Xtrordinair 44 Elite
Страница 36: ...36 of 158 ...
Страница 37: ...37 of 158 ...
Страница 49: ...49 of 158 ...
Страница 59: ...59 of 158 ...
Страница 60: ...60 of 158 ...
Страница 61: ...Travis Industries Inc Model 44 Elite Report Number 0028WF061E OMNI Test Laboratories Inc Run 5 61 of 158 ...
Страница 69: ...69 of 158 ...
Страница 70: ...70 of 158 ...
Страница 76: ...Travis Industries Inc Model 44 Elite Report Number 0028WF061E OMNI Test Laboratories Inc Run 6 76 of 158 ...
Страница 84: ...84 of 158 ...
Страница 85: ...85 of 158 ...
Страница 89: ...89 of 158 ...
Страница 90: ...90 of 158 ...
Страница 91: ...91 of 158 ...
Страница 92: ...92 of 158 ...
Страница 93: ...93 of 158 ...
Страница 94: ...94 of 158 ...
Страница 95: ...95 of 158 ...
Страница 96: ...96 of 158 ...
Страница 97: ...97 of 158 ...
Страница 98: ...98 of 158 ...
Страница 99: ...99 of 158 ...
Страница 101: ...101 of 158 ...
Страница 102: ...102 of 158 ...
Страница 103: ...103 of 158 ...
Страница 104: ...104 of 158 ...
Страница 106: ...7 20 18 106 of 158 ...
Страница 109: ...7 20 18 109 of 158 ...
Страница 111: ...111 of 158 ...
Страница 112: ...112 of 158 ...
Страница 113: ...113 of 158 ...
Страница 115: ...115 of 158 ...
Страница 130: ...130 of 158 ...
Страница 151: ...Safety Label 21 Travis Industries 10 24 2018 93508094 44 Elite Owner s 151 of 158 ...