ProBuilder 36/42CF Blower Kit (MV / GSB2)
SKU# 99000199
Page 4 of 8
17602032 - Printed 8/20/18
© Travis Industries, Inc.
Installation
1. Disable power to the fireplace (turn the service breaker off).
2. Remove the access panel from the rear of the fireplace by removing the (8) screws. Use a ¼” nut driver.
Set the access cover and screws aside for reinstallation. Locate the blower mounting studs on the bottom
of floor of the fireplace (see below).
3. Attach the wire harness to the blower assemblies. The BLUE connectors will attach to the left blower and
the RED will attach to the right (see below.)
NOTE:
Left and Right are in relation to facing the front of the appliance.
4. Locate the wires labeled “Snap Disc”. Attach the wires to the electrical posts of the included snap disc
(polarity doesn’t matter).
5. Look through the access hole in the back of the fireplace and locate the snap disc bracket. Slide the snap
disc into the bracket as shown below.
Mounting Studs
Rear of fireplace
Remove screws
and plate
Grounding Stud
L
R