 Installation 

(for qualified installers only)

 

© Travis Industries, Inc. 

4110603

 100-01265_000 

Installation Warnings 

Failure to follow all the requirements may result in property damage, bodily injury, or death. 

This firepit must be installed by a qualified installer. 

The requirements listed below are divided into sections. All requirements must be met 
simultaneously. The order of installation is not rigid – the qualified installer should follow the 
procedure best suited for the installation. 

Consult Local Regulations 

Consult

 

your

 

local

 

city

 

or

 

county

 

regulations

 

for

 

firepits

 

before

 

proceeding

 

with

 

installation.

 

Local

 

regulations

 

govern

 

building

 

and

 

using

 

firepits

 

on

 

private

 

and

 

public

 

property.

 

Some

 

cities

 

and

 

regions

 

require

 

a

 

burning

 

permit

 

before

 

starting

 

an

 

outdoor

 

fire,

 

and

 

seasonal

 

or

 

time

 

of

 

day

 

restrictions.

 

Some

 

firepit

 

regulations

 

dictate

 

the

 

type

 

of

 

materials

 

out

 

of

 

which

 

it

 

should

 

be

 

constructed.

 

Laws

 

may

 

also

 

govern

 

what

 

can

 

be

 

burned

 

in

 

a

 

firepit

 

or

 

how

 

ashes

 

are

 

disposed.

 

Placement Requirements 

For Outdoor Use Only. Install only in well-ventilated areas. 

Do

 

not

 

locate

 

the

 

firepit:

 

 

In

 

high

 

traffic

 

areas

 

 

Under

 

or

 

near

 

trees,

 

plants

 

and

 

buildings

 

where

 

debris

 

may

 

constantly

 

fall

 

into

 

the

 

firepit.

 

Excessive

 

debris

 

will

 

require

 

high

 

maintenance

 

and/or

 

cause

 

malfunctioning

 

of

 

the

 

firepit.

 

 

In

 

places

 

where

 

people,

 

children,

 

and

 

pets

 

may

 

contact

 

the

 

firepit.

 

Guards

 

or

 

fences

 

around

 

the

 

firepit

 

in

 

these

 

locations

 

are

 

recommended.

 

Clearances: 

NOTE

:

 

All

 

clearances

 

are

 

measured

 

from

 

the

 

outside

 

edge

 

of

 

the

 

firepit.

 

 

The

 

distance

 

from

 

any

 

structure

 

or

 

combustible

 

material

 

to

 

the

 

firepit

 

perimeter

 

shall

 

be

 

a

 

minimum

 

of

 

25

 

ft.

 

(7.62

 

M).

 

Lesser

 

clearances

 

shall

 

be

 

used

 

only

 

where

 

acceptable

 

to

 

the

 

local

 

authority

 

having

 

jurisdiction.

 

 

The

 

distance

 

from

 

any

 

overhanging

 

foliage

 

(trees,

 

shrubs,

 

and

 

so

 

on)

 

to

 

the

 

firepit

 

shall

 

be

 

a

 

minimum

 

of

 

15

 

feet

 

(4.572

 

M).

 

Содержание Maverick

Страница 1: ...sing property damage personal injury or loss of life www MaverickFirepit com 10 00 Copyright 2011 T I Part 100 01265_000 4800 Harbour Pointe Blvd SW Mukilteo WA 98275 Educate children and adults of the dangers of the firepit Children should be supervised when in the same area as the firepit Do not let children play with the firepit Keep pets away from the firepit ...

Страница 2: ... your dealer for details See page 13 for warranty registration details Important Information No other Maverick Firepit has the same serial number as yours The serial number is on the listing label that is chained to the firepit This serial number may be needed in case you require service Model Maverick Firepit Serial Number Purchase Date Purchased From Register your warranty online at www traviswa...

Страница 3: ...t Dimensions 5 Five Foot Model 5 Three Foot Model 5 Packing List 5 Installation Warnings 6 Consult Local Regulations 6 Placement Requirements 6 Clearances 6 Before You Begin 8 Tools Needed 8 Installation Instructions 8 Operating Instructions 11 Maintaining Your Firepit 11 Winterizing the Firepit 11 Touching up the Paint 11 Replacement Parts 12 Troubleshooting 12 ...

Страница 4: ...utdoor firepit are hot when in use To avoid burns do not touch the firepit until it has cooled completely about 45 minutes unless wearing protective gear such as potholders gloves and hot pads Never touch ashes or coals to test if they are hot Avoid breathing smoke from the fire and getting it into your eyes Do not lean over the firepit when lighting or while it is in use Do not place a hot spark ...

Страница 5: ... 5 inches 318mm Figure 1 Five Foot Model Three Foot Model Diameter 62 inches 1576mm Radius from center to Inner Ring 18 inches 458mm Radius from center to outside of Outer Ring 30 inches 762mm Inner dimension 3 feet 915mm Outer dimension 5 feet 1525mm Height 12 inches 306mm Figure 2 Three Foot Model Packing List Firepit 4 decorative covers 4 sections 8 bolts 16 washers 8 nuts NOTE The nuts and bol...

Страница 6: ...pit regulations dictate the type of materials out of which it should be constructed Laws may also govern what can be burned in a firepit or how ashes are disposed Placement Requirements For Outdoor Use Only Install only in well ventilated areas Do not locate the firepit In high traffic areas Under or near trees plants and buildings where debris may constantly fall into the firepit Excessive debris...

Страница 7: ...d installers only 7 Travis Industries Inc 4110603 100 01265_000 Figure 3 Clearances NOTE Heat from the firepit may adversely affect nearby foliage 25 7 62M 15 4 57M Gravel Soil Soil 3 76mm Non combustible material for drainage ...

Страница 8: ...o loosen the bolts before assembling to ensure correct alignment 1 Determine the location of the firepit Make sure all clearances are met see page 6 2 Prepare the firepit location We recommend 3 77mm of compacted sand or gravel under the firepit extending 12 305mm beyond the outside edge 3 Place section 1 as shown in Figure 5 place section 2 as shown in Figure 6 The pipe at the right of each secti...

Страница 9: ...e sections installing the bolts washers and nuts in each section but do not tighten yet There are top and bottom bolts for each section See the photos below Figure 9 Attaching Sections Figure 10 Attached Section With Loose Bolts 6 Tighten each bolt with the wrenches in several turns alternating the bolts This will help align the firepit Figure 11 Crescent and Ratchet Wrenches Figure 12 Tightening ...

Страница 10: ...low Figure 13 Bottom of Section Is Flush Figure 14 Top and Bottom of Sections Are Flush 7 Attach the 4 decorative bracket covers to the locations provided starting at the bottom of each section as shown below Figure 15 Attaching the Decorative Cover Figure 16 Decorative Cover Attached The completed firepit assembly should look like that in the photo below Figure 17 Completed Firepit Assembly ...

Страница 11: ...maintain may lead to malfunctioning of the firepit and potentially dangerous situations Your Maverick Firepit is designed to be cleaned and maintained easily Inspect the firepit before each use Keep the firepit clean and remove any debris that collects in or on the firepit The firepit will develop surface rust and discoloration over time this is normal Winterizing the Firepit In areas where the fi...

Страница 12: ...es Inc 4110603 100 01265_000 Replacement Parts Part Description Diagram Replacement parts can be obtained from your Maverick Firepit retailer see www maverickfirepit com Troubleshooting Problem Possible Cause Don t Call for Service Until You ...

Страница 13: ...ifices or the use of fuel other than that for which the unit is configured Units are shipped for either natural gas or propane Confirm fuel configuration with your installer 9 TRAVIS INDUSTRIES INC is free of liability for any damages caused by the appliance as well as inconvenience expenses and materials Incidental or consequential damages are not covered by this warranty In some states the exclu...

Страница 14: ... 5 Important Registration and Service Information 2 Installation Warnings 6 Maintaining Your Firepit 12 Operating Instructions 12 Overview 2 Packing List 5 Placement Requirements 6 Recommended Order of Installation 8 Replacement Parts 13 Troubleshooting 13 Winterizing the Firepit 12 ...

Отзывы: