background image

4 Safety 

Precautions 

© Travis Industries 

100-01261 

4110328 

 

 

The viewing door must be 
closed and latched during 
operation. 

Smoke from this appliance may 
active a smoke detector when 
the door is open. 

Never block free airflow through 
the air vents on this appliance. 

Gas

Gasoline or other flammable 
liquids must never be used to 
start the fire or "Freshen Up" the 
fire.  Do not store or use 
gasoline or other flammable 
liquids in the vicinity of this 
appliance. 

 

This appliance is designed and 
approved for the burning of cord 
wood only.  Do not attempt to 
burn any other type of fuel other 
than cord wood in this 
appliance, it will void all 
warranties and safety listings. 

ASHES

Ashes must be disposed in a 
metal container with a tight lid 
and placed on a non-
combustible surface well away 
from the home or structure. 

 

Do not touch the appliance while 
it is hot and educate all children 
of the danger of a high-
temperature appliance.  Young 
children should be supervised 
when they are in the same room 
as the appliance. 

36"

Keep furniture, drapes, curtains, 
wood, paper, and other 
combustibles a minimum of 36" 
away from the front of the 
appliance. 

 

This appliance must be properly 
installed to prevent the 
possibility of a house fire.  The 
instructions must be strictly 
adhered to.  Do not use 
makeshift methods or 
compromise in the installation. 

Ok

Contact your local building 
officials to obtain a permit and 
information on any installation 
restrictions or inspection 
requirements in your area.  
Notify your insurance company 
of this appliance as well. 

 

Inspect the chimney connector 
and chimney at least twice 
monthly and clean if necessary.  
Creosote may build up and 
cause a house fire. 

Do not connect this appliance to 
any chimney serving another 
appliance. 

Type 

HT

Clay 

Liner

 

This appliance must be 
connected to a listed high 
temperature (UL 103 HT) 
residential type chimney or an 
approved masonry chimney with 
a standard clay tile, or stainless 
steel liner.   

Содержание Flush Wood Plus

Страница 1: ...For your safety follow the installation directions Contact local building or fire officials about restrictions and installation inspection requirements in your area Dragon Wholesaling Pty Ltd Unit 2 1...

Страница 2: ...operation of your new appliance an easier and more enjoyable experience We offer our continual support and guidance to help you achieve the maximum benefit and enjoyment from your appliance Important...

Страница 3: ...ting Your Appliance Safety Notice 15 Before Your First Fire 15 Opening the Door 15 Bypass Operation 17 Starting a Fire 17 Adjusting the Burn Rate 19 Ash Removal 19 Blower Operation 20 Re Loading the S...

Страница 4: ...children of the danger of a high temperature appliance Young children should be supervised when they are in the same room as the appliance 36 Keep furniture drapes curtains wood paper and other combus...

Страница 5: ...seal and keep them in good condition Do not operate this heater with broken or missing glass Avoid placing wood against the glass when loading Do not slam the door or strike the glass Overfiring the...

Страница 6: ...roximate Maximum Heating Capacity in square feet 1 200 to 2 000 Maximum Burn Time Up to 10 Hours Heating capacity will vary depending on the home s floor plan degree of insulation and the outside temp...

Страница 7: ...ireplace insert yourself your authorized dealer should review your installation plans Check with local building officials for any permits required for installation of this fireplace insert and notify...

Страница 8: ...dth front 30 875 785mm d Width rear 18 875 480mm e Depth 19 483mm f Hearth Depth includes insert depth on hearth plus required hearth extension See Insert Placement Requirements on the following page...

Страница 9: ...47 25 1195mm o Front Hearth does not include insert extension x 12 300mm p Side Hearth 4 625 118mm q Front of Insert 36 915mm x Extension Onto Hearth 1 25 32mm NOTE May vary depending upon face Figure...

Страница 10: ...ox www lopi com au see the instructions included with the zero clearance box for hearth requirements When installed over a cement floor Hearth must be non combustible Face Dimensions 33 23 1 4 33 1 2...

Страница 11: ...corner firebricks and cover plates see Figure 7 a and b The bolts are pre threaded to a weld nut on the base of the insert Use a 3 4 socket wrench to screw the bolts down clockwise until the insert is...

Страница 12: ...ert in place and flue connected attach the surround panel brackets 2 Slide the surround panel into place making sure the four pins hold it into place NOTE While installing route the power cord to the...

Страница 13: ...one hole the rheostat through the other Power Cord Rheostat Wires Disconnect the molex connector leading from the power cord Use pliers to compress the strain relief from the top and bottom while pull...

Страница 14: ...ow the liner manufacturer s insturctions for installation and support Remove damper or wire it open Airtight Insulated Clean Out Combustible Mantle Flue Liner See the section Insert Placement Requirem...

Страница 15: ...while starting the first fire Open doors and windows to the room to vent these fumes This typically lasts two to four hours You may also notice oil burning off of the interior of the heater This rust...

Страница 16: ...ndle is hot To prevent smoke from entering the room open the bypass before opening the door see following page for directions You can also open the door a small amount and let air enter the firebox Ro...

Страница 17: ...lue creating more draft When pushed in the smoke goes around the baffle utilizing the secondary combustion and making the heater more efficient When starting or re loading pull the bypass out During n...

Страница 18: ...es or within the space required for charging and ash removal If using a firestarter use only products specifically designed for stoves follow the manufacturer s instructions carefully HOT WHILE IN OPE...

Страница 19: ...he Way In The air control becomes hot during operation use gloves or a tool to prevent burns The air control may take several minutes to influence the burn rate When making adjustments you may wish to...

Страница 20: ...e air control all the way push it in Open the bypass pull it out 2 Open the door slightly Let airflow inside the firebox stabilize before opening the doors fully 3 Load wood onto the fire Overnight Bu...

Страница 21: ...less creosote Testing Wood Moisture Split wood stored in a dry area will be fully dry within a year This insures dry wood If purchasing wood for immediate use test the wood with a moisture meter Some...

Страница 22: ...itions can negatively affect draft In these cases a small amount of smoke may enter the home Adding more pipe or a draft inducing cap may help Stove Does Not Burn Hot Enough Wood is Wet see the sectio...

Страница 23: ...ctor over the hearth to catch ash and protect against scratching 3 Open the doors and scoop the ash into a metal container with a tight fitting lid The closed container of ashes should be placed on a...

Страница 24: ...he nut and test operation You may need to repeat this process either moving the nut inwards or outwards until the door catch is in the correct position Door Handle Creosote Formation and Need for Remo...

Страница 25: ...a vacuum to clean the air ducts channels This prevents dust from burning and creating odors The blower should be vacuumed every year to remove any buildup of dust lint etc Remove the face Use a vacuu...

Страница 26: ...s Lay the glass gasket in the door frame cut off excess gasket Place the glass on the gasket Secure the glass clips to hold the glass in place make sure the glass clip gaskets are in place Replacing t...

Страница 27: ...prevent damage Remove the door lift off hinges 2 Remove the front two air tubes see Air Tube Removal Replacement on the following page 3 Remove front row of bricks 4 Unscrew the damper rod extension...

Страница 28: ...osened the air tube can be slid out of the air channel The pin will then disengage from the air tube you may wish to rotate the tube slightly Pivot the air tube downwards and slide it out of the air c...

Страница 29: ...5 3 251 00015 2 Brick Cut 9 x 4 5 x 2 375 2 251 00064 3 Brick Cut 9 x 4 5 x 2 34 2 251 00067 4 Brick Cut 9 x 2 75 2 251 00068 5 Brick Cut 8 x 3 5 x 2 125 2 251 00066 6 Brick Cut 9 x 3 25 2 251 00065 D...

Страница 30: ...RDANCE WITH AS NZS 4012 APPLIANCE EMISSION FACTOR BURNING HARDWOOD 1 5 g Kg REPORT NUMBER HCMG 10 058 TESTED TO AS NZS 4013 1999 Manufactured Exclusively for DRAGON WHOLESALING PTY LTD INC UNIT 2 16 L...

Страница 31: ...Listing Information 31 Travis Industries 100 01261 4110328...

Страница 32: ...7 Firebox Assembly 26 Firebox Parts 26 Firebrick and Baffle Inspection 25 Firebrick Removal Replacement 29 Floor Protection Requirements Hearth 9 Glass Cleaning 23 Glass Replacement 26 Hearth Requirem...