22
Operating Your Appliance
© Travis Industries
100-01261
4110328
Troubleshooting
Problem
Possible Cause
Smoke Enters Room During
Start-Up
•
Open the bypass (pg. 17).
•
Open the air control (pg. 19).
•
Cold Air Blockage - burn a piece of newspaper to
establish a draft.
•
If the flame is not getting enough air, a small crack in
the door is all that is needed.
Kindling Does Not Start - Fire
Smolders
•
Open the bypass (pg. 17).
•
Open the air control (pg. 19).
•
Not enough starter paper - use additional newspaper if
necessary.
•
If the flame is not getting enough air, a small crack in
the door is all that is needed.
Smoke Enters Room While Re-
Loading
•
Open the bypass before opening the door (pg. 17).
•
Open the air control before opening the door (pg. 19).
•
Let the air stabilize before fully opening the door.
Then open the door approximately 1 inch. Let air go
into the firebox for a few seconds. Once the smoke
appears to be flowing up the chimney consistently,
open the door.
•
Insufficient Draft - Chimney height and outside
conditions can negatively affect draft. In these cases a
small amount of smoke may enter the home. Adding
more pipe or a draft-inducing cap may help.
Stove Does Not Burn Hot Enough
•
Wood is Wet - see the section "Selecting Wood" on
page 21 for details on wood.
•
Make sure the air control is all the way open. Slide the
control back and forth to insure the control is not stuck.
•
Insufficient Draft - Chimney height and outside
conditions can negatively affect draft. In these cases
the fire may burn slowly. Adding more pipe or a draft-
inducing cap may help.
Blower Does Not Run
•
Stove is Not Up to Temperature - This is normal. The
blower will come on when the stove is hot - usually 15
to 30 minutes.
•
Electricity is Cut to the Blower - Check the household
breaker or fuse to make sure it is operable.
Stove Does Not Burn Long
Enough
•
Depending upon wood, draft, and other factors, the
burn time may be shorter then stated. Make sure the
doors are sealing and not allowing air into the firebox -
See the section "Door and Glass Inspection" on page
24 for details.
•
Check the ash bed for coals. Often, coals are still
glowing under a slight bed of flyash. By raking these