Fireplace Insert Installation
(for qualified installers only)
11
© Travis Industries
100-01261
4110328
Insert Rollers
Two rollers are built into the back edge of the insert. This
allows the insert to be rolled into position by lifting the front
of the insert and pushing it into position (see
Figure 6
).
Figure 6
Leveling Bolt Installation
MASONRY NOTE
: Place a metal plate below the
bolts on masonry fireplaces to prevent damage to the
floor brick.
Two leveling bolts are pre-installed on the insert to
allow for proper leveling within the fireplace. To
access the bolts, remove the back corner firebricks
and cover plates (see
Figure 7
“a” and “b”) The bolts
are pre-threaded to a weld-nut on the base of the
insert. Use a 3/4” socket wrench to screw the bolts
down (clockwise) until the insert is level (see “c”).
SEALING THE COVER PLATE
: We recommend
sealing the cover plate with furnace cement (place on
underside of cover plate).
BOLT LENGTH
: The included bolts allow
approximately 1” of rise. If additional rise is required,
use a longer 1/2-13 thread bolt. Make sure the
additional bolt length does not interfere with the cover
plate.
a
b
c
Figure 7
Flue Installation
Included in the owner’s pack are
three “flue brackets” and six self-
drilling screws. Use these
components to secure the flue to the
fireplace insert.
Flue Opening
Flue (flexible or rigid)
Flue Bracket