background image

22 

Operating Your Appliance 

© Travis Industries 

100-01261 

4110328 

Troubleshooting 

Problem 

Possible Cause 

Smoke Enters Room During 
Start-Up 

 

Open the bypass (pg. 17). 

 

Open the air control (pg. 19). 

 

Cold Air Blockage - burn a piece of newspaper to 
establish a draft. 

 

If the flame is not getting enough air, a small crack in 
the door is all that is needed. 

Kindling Does Not Start - Fire 
Smolders 

 

Open the bypass (pg. 17). 

 

Open the air control (pg. 19). 

 

Not enough starter paper - use additional newspaper if 
necessary. 

 

If the flame is not getting enough air, a small crack in 
the door is all that is needed. 

Smoke Enters Room While Re-
Loading 

 

Open the bypass before opening the door (pg. 17). 

 

Open the air control before opening the door (pg. 19). 

 

Let the air stabilize before fully opening the door.  
Then open the door approximately 1 inch.  Let air go 
into the firebox for a few seconds.  Once the smoke 
appears to be flowing up the chimney consistently, 
open the door. 

 

Insufficient Draft - Chimney height and outside 
conditions can negatively affect draft.  In these cases a 
small amount of smoke may enter the home.  Adding 
more pipe or a draft-inducing cap may help. 

Stove Does Not Burn Hot Enough

 

Wood is Wet - see the section "Selecting Wood" on 
page 21 for details on wood. 

 

Make sure the air control is all the way open.  Slide the 
control back and forth to insure the control is not stuck.

 

Insufficient Draft - Chimney height and outside 
conditions can negatively affect draft.  In these cases 
the fire may burn slowly.  Adding more pipe or a draft-
inducing cap may help. 

Blower Does Not Run 

 

Stove is Not Up to Temperature - This is normal.  The 
blower will come on when the stove is hot - usually 15 
to 30 minutes. 

 

Electricity is Cut to the Blower - Check the household 
breaker or fuse to make sure it is operable. 

Stove Does Not Burn Long 
Enough 

 

Depending upon wood, draft, and other factors, the 
burn time may be shorter then stated.  Make sure the 
doors are sealing and not allowing air into the firebox - 
See the section "Door and Glass Inspection" on page 
24 for details. 

 

Check the ash bed for coals.  Often, coals are still 
glowing under a slight bed of flyash.  By raking these 
into a pile you can re-start your stove quickly. 

 

Содержание Flush Plus

Страница 1: ...For your safety follow the installation directions Contact local building or fire officials about restrictions and installation inspection requirements in your area Dragon Wholesaling Pty Ltd Unit 2 1...

Страница 2: ...operation of your new appliance an easier and more enjoyable experience We offer our continual support and guidance to help you achieve the maximum benefit and enjoyment from your appliance Important...

Страница 3: ...ting Your Appliance Safety Notice 15 Before Your First Fire 15 Opening the Door 15 Bypass Operation 17 Starting a Fire 17 Adjusting the Burn Rate 19 Ash Removal 19 Blower Operation 20 Re Loading the S...

Страница 4: ...children of the danger of a high temperature appliance Young children should be supervised when they are in the same room as the appliance 36 Keep furniture drapes curtains wood paper and other combus...

Страница 5: ...seal and keep them in good condition Do not operate this heater with broken or missing glass Avoid placing wood against the glass when loading Do not slam the door or strike the glass Overfiring the...

Страница 6: ...roximate Maximum Heating Capacity in square feet 1 200 to 2 000 Maximum Burn Time Up to 10 Hours Heating capacity will vary depending on the home s floor plan degree of insulation and the outside temp...

Страница 7: ...ireplace insert yourself your authorized dealer should review your installation plans Check with local building officials for any permits required for installation of this fireplace insert and notify...

Страница 8: ...dth front 30 875 785mm d Width rear 18 875 480mm e Depth 19 483mm f Hearth Depth includes insert depth on hearth plus required hearth extension See Insert Placement Requirements on the following page...

Страница 9: ...include insert extension x 12 300mm p Side Hearth 4 625 118mm q Front of Insert 36 915mm x Extension Onto Hearth 1 25 32mm NOTE May vary depending upon face Figure 3 Mantel Leg Column Clearances Mante...

Страница 10: ...Xtrordinair Arched Lopi Wilmington Figure 4 Drafting Performance This appliance relies upon natural draft to operate External forces such as wind barometric pressure topography or factors of the home...

Страница 11: ...corner firebricks and cover plates see Figure 7 a and b The bolts are pre threaded to a weld nut on the base of the insert Use a 3 4 socket wrench to screw the bolts down clockwise until the insert is...

Страница 12: ...ert in place and flue connected attach the surround panel brackets 2 Slide the surround panel into place making sure the four pins hold it into place NOTE While installing route the power cord to the...

Страница 13: ...one hole the rheostat through the other Power Cord Rheostat Wires Disconnect the molex connector leading from the power cord Use pliers to compress the strain relief from the top and bottom while pull...

Страница 14: ...ow the liner manufacturer s insturctions for installation and support Remove damper or wire it open Airtight Insulated Clean Out Combustible Mantle Flue Liner See the section Insert Placement Requirem...

Страница 15: ...while starting the first fire Open doors and windows to the room to vent these fumes This typically lasts two to four hours You may also notice oil burning off of the interior of the heater This rust...

Страница 16: ...ndle is hot To prevent smoke from entering the room open the bypass before opening the door see following page for directions You can also open the door a small amount and let air enter the firebox Ro...

Страница 17: ...lue creating more draft When pushed in the smoke goes around the baffle utilizing the secondary combustion and making the heater more efficient When starting or re loading pull the bypass out During n...

Страница 18: ...es or within the space required for charging and ash removal If using a firestarter use only products specifically designed for stoves follow the manufacturer s instructions carefully HOT WHILE IN OPE...

Страница 19: ...he Way In The air control becomes hot during operation use gloves or a tool to prevent burns The air control may take several minutes to influence the burn rate When making adjustments you may wish to...

Страница 20: ...e air control all the way push it in Open the bypass pull it out 2 Open the door slightly Let airflow inside the firebox stabilize before opening the doors fully 3 Load wood onto the fire Overnight Bu...

Страница 21: ...less creosote Testing Wood Moisture Split wood stored in a dry area will be fully dry within a year This insures dry wood If purchasing wood for immediate use test the wood with a moisture meter Some...

Страница 22: ...itions can negatively affect draft In these cases a small amount of smoke may enter the home Adding more pipe or a draft inducing cap may help Stove Does Not Burn Hot Enough Wood is Wet see the sectio...

Страница 23: ...ctor over the hearth to catch ash and protect against scratching 3 Open the doors and scoop the ash into a metal container with a tight fitting lid The closed container of ashes should be placed on a...

Страница 24: ...he nut and test operation You may need to repeat this process either moving the nut inwards or outwards until the door catch is in the correct position Door Handle Creosote Formation and Need for Remo...

Страница 25: ...a vacuum to clean the air ducts channels This prevents dust from burning and creating odors The blower should be vacuumed every year to remove any buildup of dust lint etc Remove the face Use a vacuu...

Страница 26: ...s Lay the glass gasket in the door frame cut off excess gasket Place the glass on the gasket Secure the glass clips to hold the glass in place make sure the glass clip gaskets are in place Replacing t...

Страница 27: ...prevent damage Remove the door lift off hinges 2 Remove the front two air tubes see Air Tube Removal Replacement on the following page 3 Remove front row of bricks 4 Unscrew the damper rod extension...

Страница 28: ...osened the air tube can be slid out of the air channel The pin will then disengage from the air tube you may wish to rotate the tube slightly Pivot the air tube downwards and slide it out of the air c...

Страница 29: ...5 3 251 00015 2 Brick Cut 9 x 4 5 x 2 375 2 251 00064 3 Brick Cut 9 x 4 5 x 2 34 2 251 00067 4 Brick Cut 9 x 2 75 2 251 00068 5 Brick Cut 8 x 3 5 x 2 125 2 251 00066 6 Brick Cut 9 x 3 25 2 251 00065 D...

Страница 30: ...RDANCE WITH AS NZS 4012 APPLIANCE EMISSION FACTOR BURNING HARDWOOD 1 5 g Kg REPORT NUMBER HCMG 10 058 TESTED TO AS NZS 4013 1999 Manufactured Exclusively for DRAGON WHOLESALING PTY LTD INC UNIT 2 16 L...

Страница 31: ...Listing Information 31 Travis Industries 100 01261 4110328...

Страница 32: ...7 Firebox Assembly 26 Firebox Parts 26 Firebrick and Baffle Inspection 25 Firebrick Removal Replacement 29 Floor Protection Requirements Hearth 9 Glass Cleaning 23 Glass Replacement 26 Hearth Requirem...

Отзывы: