Installation
(for qualified installers only)
© Travis Industries
4041213
1 0 0 - 0 1 1 5 2
Venting Configurations with a Horizontal Termination
The termination must fall within the shaded area shown in the chart. Use the indicated restrictor position.
AAAAAAAAAAAAAA
AAAAAAAAAAAAAA
AAAAAAAAAAAAAA
AAAAAAAAAAAAAA
AAAAAAAAAAAAAA
AAAAAAAAAAAAAA
AAAAAAAAAAAAAA
AAAAAAAAAAAAAA
AAAAAAAAAAAAAA
AAAAAAAAAAAAAA
AAAAAAAAAAAAAA
AAAAAAAAAAAAAA
AAAAAAAAAAAAAA
AAAAAAAAAAAAAA
5 feet
0 feet
0 feet
0 feet
NOTE:
Horizontal sections require a 1/4" rise every 12" of travel.
The maximum vertical height is 11' - two 4' sections
The maximum horizontal length is 16' - four 4' sections
16 ' (Max)
Restrictor
Position # 1
5 feet
11' Max
10 feet
16 ' (Max)
5 feet
10 feet
5 feet
0 feet
11' Max
Restrictor
Position # 2
NOTE:
Restrictor positions are based upon lab tests. The
ideal restrictor position may vary slightly, especially
when the termination is near a demarkation line.
WARNING:
When using an elbow directly off the
top of the fireplace, a 2" clearance
above the vent is required.