Page 20
17602010 - 12/15/17
Convection Blower Removal
Make sure the stove has fully cooled (approximately 25 minutes) before conducting service. Unplug the
stove to prevent electrical shock.
Both blowers remove the same way. If the left blower is being removed, remove the PCB and shield first
(see section “PCB removal”)
1. Remove the side rear panel (see section “Rear Panel Removal”)
2. Remove the (4) screws that mount the blower to the mounting bracket (set aside for reinstallation).
NOTE:
The rear two screws can be removed with a nut driver. The front (2) will require a small ratchet or
box wrench.
3. Remove the fan from the stove and disconnect the wires from motor.