Convection Blower Circuit Faulty
The convection blower is controlled directly by the circuit board. . Follow the directions below to check the convection
blower circuit.
Make sure the stove has fully cooled (approximately 25 minutes) before conducting service. Unplug the
stove to prevent electrical shock.
Attach the multimeter leads, set to voltage AC, to the
two posts on the convection blower (there is enough
bare metal on the post to get a good reading).
Convection Blower
Convection Blower
(shown removed)
Start the stove and let it
reach normal operating
temperature (10 to 15
minutes).
The voltage should read approximately 70 volts on low
blower speed, approximately 115 volts on high blower
speed.
a
b
c
VOLTS
AC
Convection Blower Wires
(Brown & White)
If No Voltage is Detected
Check the brown and white wires leading to the blower for
breaks or damage. Replace the wiring harness if damage is
found. Othewise, the circuit board (or system snap disk) is
faulty. Replace these components and re-test the stove.