Fireplace
Insert
Installation
(for qualified installers only)
23
© Travis Industries
93508061
4050526
Insert with
Positive
Connection
Figure 20
Insert with Direct
Connection
(Masonry
Fireplace)
NOTE
:
Direct connections
require installation of
an airtight block-off
plate or damper
adapter (see "Block-off
Plate Installation" on
page 22).
The liner must be
stainless steel
connector or flexible
vent. Follow the liner
manufacturer's
insturctions for
installation and
support.
Remove damper
or wire it open
Airtight Insulated
Clean-Out
Combustible Mantle
Flue Liner
See the section "Insert
Placement Requirements" for
minimum clearances and
hearth required.
Cap (prevents water
from entering)
Install a non-combustible
cover plate to prevent water
from entering the chimney
Surround Panels
Block-off plate or
damper adapter
Remove
damper
or wire it
open
Airtight
Insulated
Clean-Out
Stainless steel
chimney connector
must Extend 1' past
the block-off plate or
to the flue liner
Combustible Mantle
Flue
Liner
See the section
"Insert Placement
Requirements" for
minimum clearances
and hearth required.
Surround Panels