36 Operation
© Travis Industries
4140811
100-01331
Manual On-Off / Smart Thermostat / Standard Thermostat
Use the thermostat button to cycle through the three thermostat settings (see Figure 6).
Figure 6
MANUAL ON/OFF
– The burner will turn on and off using the remote (see Figure 7). Press the
On/Off button to control the burner. When off, the display will only show the current temperature.
Figure 7
SMART THERMOSTAT
– While in Smart Thermostat mode, the transmitter will control the
burner to achieve the target temperature (see Figure 8 below). Flame height will be adjusted up
or down to allow operation without turning the burner on and off (also called “smart modulation”).
To adjust the target temperature, press the UP and DOWN buttons until a suitable temperature is
achieved.
Figure 8
STANDARD THERMOSTAT
- While in Standard Thermostat mode, the transmitter will turn the
burner on and off to achieve the target temperature (see Figure 9 below). To adjust the target
temperature, press the up and down buttons until a suitable temperature is achieved.
Figure 9
NOTE:
If the transmitter batteries go dead while in thermostat setting (standard or smart), the appliance
will shut off after approximately 24 hours.
ON
F
OFF
ON
SMART
Look here for the
thermostat setting.
Press the thermostat button to cycle
through the thermostat settings.
F
OFF
When in manual setting, the
word "OFF" will appear here.
F
When in smart thermostat
setting, the word "SMART"
will appear here.
This is the target
temperature on the read-
out. Use the up or down
buttons to adjust the target
temperature.
SMART
F
ON
When in standard thermostat
setting, the word "ON" will
appear here.
This is the target
temperature on the
read-out. Use the up or
down buttons to adjust
the target temperature.