background image

 

Installation

 (

for qualified installers only)

 

37 

© Travis Industries 

4141013 

100-01414

 

Steps for Finalizing the Installation 

1.  Remove the glass. 

NOTE: If using propane (LP) convert the appliance prior to installing the logs. 

2.  We recommend you purge the gas line at this time (with the glass removed).  This allows gas to be detected 

once it enters the firebox, ensuring gas does not build up.  

3.  Make sure the accent light bulbs are in place.  

NOTE

: Take care to not touch the bulbs with your fingers (use a cloth or paper towel). 

4.  Install the four AA batteries (see illustration below).  The AA batteries act as a power backup in case the 

household (AC) power goes out and are required for operation.    Install three AAA batteries into the remote (see 
illustration below).  Synchronize the transmitter to the IFC. 

 

 

 

5.  Install the burner and media (and firebacks if applicable). 
6.  Replace the glass. 
7.  Start the heater.   
8.  Leak test all gas joints.   

AAA Battery

AAA Battery

°F

AAA Battery

AA Battery

AA Battery

AA Battery

AA Battery

Содержание 564 HO GSR2

Страница 1: ...not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call gas supplier from a neighbor s phone Follow the gas supplier s instructions If...

Страница 2: ...stment alteration service or maintenance can cause injury or property damage Refer to the owner s information manual provided with this appliance For assistance or additional information consult a qua...

Страница 3: ...tions with Horizontal Termination EmberFyre Burner only 21 Vent Configurations with Vertical Termination EmberFyre Burner only 22 Vent Configurations with Horizontal Termination Dancing DiamondFyre 23...

Страница 4: ...t gases must be vented outside the structure of the living area Combustion air is drawn from outside the living area structure The venting must not be connected to a chimney flue serving a separate so...

Страница 5: ...is provided with this appliance and shall be installed for the protection of children and other at risk individuals If the barrier becomes damaged the barrier shall be replaced with the manufacturer...

Страница 6: ...ting Capacity in square meters Up to 158 Up to 158 Maximum MJ Input Per Hour 36 9 36 9 Heating capacity will vary with floor plan insulation and outside temperature Dimensions 36 25 921mm Weight 165 L...

Страница 7: ...ble below to verify you have all of the items required Burner Style EmberFyre Burner 96900116 DiamondFyre Burner 96900115 DancingFyre Burner 96900114 Firebacks Requires 564 Ceramic Firebacks 96100179...

Страница 8: ...ng Install the vent gas line and electrical hook up Install the drywall Install the hearth if applicable Install the facing if applicable Install the mantel if applicable Finalize the installation see...

Страница 9: ...arpet This heater may be placed in a bedroom Please be aware of the large amount of heat this appliance produces when determining a location Clearances When installed walls in front of the fireplace m...

Страница 10: ...10 Installation for qualified installers only 10 Travis Industries 4141013 100 01414 Minimum Framing Dimensions a Minimum Enclosure Height 36 5 928mm 36 75 936mm 17 75 451mm 56 1423mm a...

Страница 11: ...tab out 90 use a screwdriver if necessary Fireplace Drywall Framing Nailing Bracket TOP VIEW 1 2 13mm Drywall 5 8 16mm Drywall There are four nailing brackets on the front of the fireplace Follow the...

Страница 12: ...only 12 Travis Industries 4141013 100 01414 Corner Installations A typical 45 installation uses the framing dimensions shown in the illustration below NOTE all clearances still apply 14 1 4 362mm Mini...

Страница 13: ...y pressure testing of that system at test pressures in excess of 1 2 psig 3 5 kPA For pressures under 1 2 psig kPA isolate the gas supply piping by closing the manual shutoff valve Leak test all gas l...

Страница 14: ...fireplace on the right side 2 Remove the screw that holds the shutoff valve plate in place 1 4 nutdriver Remove the shutoff valve plate 3 Remove the cover plate from the left side of the fireplace it...

Страница 15: ...er is shut off prior to working on any electrical lines The appliance when installed must be electrically grounded in accordance with local codes or in the absence of local codes with the National Ele...

Страница 16: ...must maintain the required clearance to combustible materials to prevent a fire Do not fill air spaces with insulation Sides 1 25mm Above 4 102mm Below 1 25mm Altitude Considerations This heater has...

Страница 17: ...tructions for Simpson Dura Vent may be found at www duravent com Other vents may be approved Vent Installation Slide the vent sections together and turn 1 4 turn until the sections lock in place Screw...

Страница 18: ...the restrictor positions The charts for acceptable vent configurations detail the correct restrictor positions Exhaust Restrictor Adjustment The exhaust restrictor is shipped in position 1 If the rest...

Страница 19: ...nstalling this component Make sure to adjust the intake restrictor to the position indicated on the vent configuration page To adjust the restrictor loosen the two screws securing the restrictor to th...

Страница 20: ...the diffuser to position 2 as follows 1 The diffuser is located above the exhaust restrictor remove the restrictor if necessary 2 Remove the diffuser 3 Bend the round portion of the diffuser so it is...

Страница 21: ...m 0 feet 5 feet 1 5m 10 feet 3m 15 feet 4 5m 20 max 6m 15 feet 4 5m 21 max 6 4m 21 max 6 4m Exhaust Restrictor 5 2 LP 4 NG Maximum Exhaust Restrictor 1 Intake Restrictor 1 Diffuser Position 1 CLOSED E...

Страница 22: ...onsidered a vertical elbow Horizontal length max 24 is calculated by adding both lengths of horizontal run Horizontal Length H1 H2 5 feet 1 5m 0 feet 0 feet 5 feet 1 5m 0 feet 20 feet 6m 20 feet 6m 5...

Страница 23: ...0 feet 5 feet 1 5m 10 feet 3m 15 feet 4 5m 20 max 6m 10 feet 3m 15 feet 4 5m 21 max 6 4m 21 max 6 4m Exhaust Restrictor 5 2 LP 4 NG Maximum Exhaust Restrictor 1 Intake Restrictor 1 Diffuser Position...

Страница 24: ...a 90 or 45 elbow This is considered a vertical elbow Horizontal length max 24 is calculated by adding both lengths of horizontal run Horizontal Length H1 H2 5 feet 1 5m 0 feet 0 feet 5 feet 1 5m 0 fe...

Страница 25: ...es and the requirements of the gas supplier G Minimum 48 1219mm clearance from any adjacent building H Minimum 84 2134mm clearance above any grade when adjacent to public walkways or driveways NOTE ma...

Страница 26: ...ring the fireplace must be raised so the base of the unit is above the carpet surface or flooring material Floor Mounted Fireplaces Raised Fireplaces WARNING A non combustible hearth is not required H...

Страница 27: ...laced above the non combustible facing see b below and to the sides and below the fireplace face This combustible facing must be a minimum 3 77mm above the face of the fireplace see b below Tile or ot...

Страница 28: ...28 Installation for qualified installers only 28 Travis Industries 4141013 100 01414...

Страница 29: ...Installation for qualified installers only 29 Travis Industries 4141013 100 01414...

Страница 30: ...is location 1 25mm above the base of the fireplace The fireplace may be raised to accommodate thicker hearth materials Optional Faceplates Sizing Chart Name Height Width Notes FPX Artisan Classic Fr C...

Страница 31: ...convection air 27 3 4 705mm 1 1 7 8 48mm 32 1 2 826mm 1 1 2 38mm Tile 7 1 2 191mm 1 5 8 41mm Attach the facing to this edge of the fireplace Tile Line Tile Line Hearth Line Tile Line Floor mounted fir...

Страница 32: ...ce Note how the facing extends 1 25mm above the base of the fireplace 1 25mm Fireplace Support Floor Tile or other facing under 1 25mm thick Face Floor Max 1 25mm Hearth note how it extends under the...

Страница 33: ...y Raised Fireplaces Masonry is installed 1 25mm maximum above the base of the fireplace Floor Mounted Fireplaces or Raised Hearths Build the hearth 1 maximum 25mm above the base of the fireplace The f...

Страница 34: ...pper corners FRONT VIEW TOP VIEW 61 Radius 1549mm 2 3 4 70mm 29 737mm 36 1 4 921mm Masonry Line Hearth Line The Fireplace Xtrodinair 564 Masonry Template is recommended for masonry installation sku 98...

Страница 35: ...e masonry extends 1 25mm above the base of the fireplace 1 25mm Fireplace Support Floor Floor Mounted Fireplace with Hearth SIDE OF FIREPLACE Masonry or other non combustible over 1 25mm thick Face Fl...

Страница 36: ...he side of the glass frame 0 from side of fireplace Combustible mantel columns legs that protrude between 19mm and 4 102mm from the glass frame or non combustible facing require a 5 127mm clearance to...

Страница 37: ...bulbs are in place NOTE Take care to not touch the bulbs with your fingers use a cloth or paper towel 4 Install the four AA batteries see illustration below The AA batteries act as a power backup in c...

Страница 38: ...his heater For comprehensive operating and maintenance instructions refer to the Owner s Manual ACID WASH WARNING Before installing the faceplate make sure any masonry that has been treated with acid...

Страница 39: ...urer s barrier for this appliance If using a face or grill that requires use of a cove cover use the cove cover included with the fireplace see below Do not use the cover included with face or grill i...

Страница 40: ...nstructions included with the face for details Open the 4 latches holding the glass frame in place starting with the bottom Follow the instructions shown to the right Latch Glass Top of Firebox Lift t...

Страница 41: ...rn when it is disengaged Follow the directions below to re install the latch if it becomes loose Top of Firebox Hold the latch at an angle and insert it into the slot on the glass frame anchor NOTE th...

Страница 42: ...lt causing property damage personal injury or loss of life The qualified service agency is responsible for the proper installation of this kit The installation is not proper and complete until the ope...

Страница 43: ...Replace the orifices as shown below Orifice Front Rear NG 50 44 LP 1 1mm 55 3 Install the LP burner bracket and manifold seal plate as shown below These components are shipped with the fireplace Front...

Страница 44: ...the Natural Gas NG orifice Place the LP orifice in the pilot assembly then replace the pilot hood tightening the pilot hood until it is snug do not over tighten 5 Remove the concealment cover Unscrew...

Страница 45: ...ation sheet included with it make sure to follow all of the directions Place the stepper motor on the gas control valve MAKE SURE IT IS CORRECTLY ORIENTED Secure using the screws included with the mot...

Страница 46: ...n 13 Gas Line Location 13 Gas Line Requirements 13 Hearth Requirements 26 Heating Specifications 6 Installation Options 6 Intake Restrictor Adjustment 19 Error Reference source not found 2 Mantel Requ...

Отзывы: