From the SETUP screen, select SYS PAR to get:
Press to select SYS PAR.
Press to select SYS PAR.
Press to decrease ITEM.
Press to increase ITEM.
Press to decrease VALUE.
Press to increase VALUE.
Press to return to MAIN MENU*
Press to return to SETUP with saving.
*without saving.
1) SET CLOCK
a)
MONTH (JANUARY – DECEMBER)
b)
DATE (1 – 31
1
)
c)
YEAR (2003 – 2079)
d)
DAY OF WEEK (SUNDAY – SATURDAY)
e)
HOUR (0 – 23)
f)
MINUTE (0 – 59)
g)
DLS TIME (ENABLED – DISABLED)
2) PROBES
a)
1 (ON – OFF) b)
2 (ON – OFF)
c)
3 (ON – OFF)
3) DISPLAY
a)
TEMPERATURES (IN DEG C – IN DEG F)
4) LOGGING
a)
TIME (5-MINUTES – 30-MINUTES)
5) ALARM
a)
CYCLE RUNNING (NO – yes)
b)
CYCLE ENDS (NO – yes)
c)
PRINTER ERROR (NO – yes)
d)
HIGH/LOW TEMP (no – YES)
e)
POWER FAILURE (no – YES)
6) REMINDERS
a)
DOOR OPEN (0 – 2 MINUTES)
7) BLAST
a)
TARGET (33 – 40)
b)
AIR (10 – 40)
c)
HOLD (10 – 40)
d)
HIGH ALARM (35 – 60)
e)
LOW ALARM (-30 – 34)
8) SOFT CHILL
a)
BY TEMP (5 – 20)
b)
BY TIME (10 – 90)
c)
2ND TEMP (10 – 40)
9) FREEZE CHILL
a)
TARGET (-22 – 28)
b)
AIR (-32 – 20)
c)
HOLD (10 – 40)
d)
HIGH ALARM (20 – 45)
e)
LOW ALARM (-30 – 0)
10) RESET
a)
PARAMETERS (YES – NO)
1
Last day is corrected for month and leap year.
VII. OPERATING THE BLAST CHILL CONTROL - SYSPAR
-21-
VII. j - SYSPAR - SETTING THE VARIOUS CONTROL FEATURES:
By accessing SYSPAR (system parameters), the operator can adjust many
control features to better suit their operational needs, such as: Clock Settings,
Probes, Temperature Scale (F or C), Alarm Settings and Chill Parameters. It
also provides for an easy return to the original factory default settings with a
RESET feature.
SYS PAR: SET CLOCK
ITEM:MONTH
VALUE:APRIL
CANCEL ENTER
SYS PAR Menu Display
SYS PAR: SET CLOCK
ITEM:MONTH
VALUE:
APRIL
CANCEL ENTER
SYS PAR: SET CLOCK
ITEM:DATE
VALUE:04/
XX
/00
CANCEL ENTER
SYS PAR: SET CLOCK
ITEM:YEAR
VALUE:04/14/
XX
CANCEL ENTER
SYS PAR: SET CLOCK
ITEM:HOUR
VALUE:
XX
:00
CANCEL ENTER
SYS PAR: SET CLOCK
ITEM:MINUTE
VALUE:10:
XX
CANCEL ENTER