![Trapzilla TSS-27 Скачать руководство пользователя страница 21](http://html1.mh-extra.com/html/trapzilla/tss-27/tss-27_installation-and-maintenance-instructions-manual_1152985021.webp)
©2014 Thermaco, Inc. All rights reserved • Patented/Patents Pending • Specifications subject to change without notice
Thermaco, Inc. • 646 Greensboro St. • Asheboro, N. C. 27204-2548 • Phone (336) 629-4651
MNL-TSS 21
A THERMACO® Technology
Section III: TSS Installation
In-Ground Installation
In order to offset the effects of buoyancy caused by groundwater (high water ta-
bles), Thermaco, Inc. recommends concrete be poured around the anchor ring
and the Trapzilla
®
units installed in-ground. The amount of concrete to be used
is specified in the table below. The concrete is to be poured continuously and
completely surrounding the Trapzilla
®
Solids Separator (and Extension Collars if
applicable) to ensure proper strength and security.
Buoyancy Calculations TSS Models/Components
Amount of Concrete
TSS Model
Weight (lbs.)
Volume (Cu. Yards)
TSS-95-ECA
1975
0.50
TSS-70-ECA
1525
0.40
TSS-27-ECA
550
0.15
ECA-TSS-29*
600
0.20
* AMOUNT OF CONCRETE TO BE ADDED FOR EACH EXTENSION COLLAR
TSS-95-ECA
ECA-TSS-18
ECA-TSS-29
Pictured Left:
Installation of TSS-95-ECA unit
with Built-In 18” Extension Collar
fully extended and 29” Two-Piece
Extension Collar fully extended for
a total of 47” of additional depth
for unit. Concrete should fully
encircle the unit up to the surface.
A small amount of space (up to 4”)
may be left unfilled to cover with
dirt and grass if installed outside.