![Trapzilla TSS-27 Скачать руководство пользователя страница 13](http://html1.mh-extra.com/html/trapzilla/tss-27/tss-27_installation-and-maintenance-instructions-manual_1152985013.webp)
©2014 Thermaco, Inc. All rights reserved • Patented/Patents Pending • Specifications subject to change without notice
Thermaco, Inc. • 646 Greensboro St. • Asheboro, N. C. 27204-2548 • Phone (336) 629-4651
MNL-TSS 13
A THERMACO® Technology
Section III: TSS Installation
1
1
2
2
3
3
4
4
A
A
B
B
C
C
D
D
THIS DRAWING CONTAINS PROPRIETARY AND PATENTED MATERIAL. THIS DRAWING MAY NOT BE REPRODUCED IN WHOLE OR PART WITHOUT
WRITTEN CONSENT FROM THERMACO, INC. POSSESSION OF THIS DRAWING DOES NOT CONSTITUTE THE RIGHT TO MANUFACTURE.
POSSESSION OF THIS DRAWING DOES CONSTITUTE AN IMPLIED NONDISCLOSURE AGREEMENT BETWEEN THERMACO, INC. AND THE HOLDER OF
THIS DRAWING. DO NOT DESTROY THIS DRAWING, IT IS THE SOLE PROPERTY OF THERMACO, INC. AND MUST BE RETURNED UPON REQUEST.
MATERIAL (UNLESS NOTED)
FINISH (UNLESS NOTED)
646 GREENSBORO STREET
PO BOX 2548, ASHEBORO, NC 27203
VOICE 336-629-4651 FAX 336-626-5739
Decimals
.XX +/- .03
.XXX +/- .015
Unless otherwise specified
Dimensions are in inches
Tolerances
Angular
+/- 1°
CHECKED
SIZE
REV. NO.
DWG NO.
PART NO.
C
SCALE
RELEASE DATE
SHEET OF
ENGINEERING
DRAWN
DATE
THIRD ANGLE PROJECTION
Outlet
Outlet
Cleanout*
Cleanout*
Cleanout*
Cleanout*
Cleanout*
Cleanout*
Inlet
Trapzilla
TSS-95 unit
Trapzilla
TZ-600 unit
Trapzilla
TZ-600 unit
Outlet Vent
(Connect to
facility vent)
4" (100mm) Flow Splitter
*Use a 4" (100 mm) Two-Way Cleanout for TSS-70,
TSS-95, TZ-400 and TZ-600 Unit Installations
One Solids Separator and Two Trapzilla Units
A single Trapzilla Solids Separator and two Trapzilla Grease Interceptors should be installed
by placing the Solids Separator in line and then using a Flow Splitter to divert the water flow to
two separate Trapzilla units in parallel. Place Two-Way Cleanouts before, between and after
the units as shown below, including before and after the flow splitter. Make sure to connect an
outlet vent after the Trapzilla Grease Interceptor. A Low Head Flow Control (LHFC) is shipped
with each unit, and if needed should only be installed after the first Cleanout and before the
Trapzilla Solids Separator.
Note: Drawing for reference only. Equipment must be installed in compli-
ance with all applicable laws, regulations and codes, including plumbing
codes. Installation should be performed by a qualified plumber.
Configurations
*Use a 4” (100 mm) Two-Way Cleanout for TSS-70,
TSS-95, TZ-400 and TZ-600 Unit Installations