M
ENU
F
UNCTIONS
Operator Manual Rev 1.1
Page 29
TALLY
SOURCE: EXTERNAL / SDI EMBEDDED
Tally can be activated via an EXTERNAL signal (GPI) or via the camera REC/STOP command
embedded in the SDI (if any).
When activated via EXTERNAL, the Tally state conditions are adjustable in MENU / TECHNICAL /
GPI.
In wireless mode Tally may be activated via the transmitter:
-
through EXTERNAL signal using 1 of the 2 GPI of the transmitter
-
through the camera REC/STOP command embedded in the SDI (if any)
LED ON/OFF
Activates or deactivates the TALLY LED on the front panel.
TALLY BLINKING/FIX
Sets the active mode in TALLY ON
STYLE
Selects the style of the TALLY
Includes the TALLY FRAME which is active on FRAME3 of the frameline.