04. DISA & ECF Access Delay Time - Day
This parameter sets the timer that a DISA/ECF (External Call Forwarding) trunk will ring assigned stations (set by
Program 01-tk-IP, 02-tk-IP) prior to be connected to Auto Attendant (DISA) or another Trunk (ECF) in Day mode.
Stations can answer the incoming trunk before it is connected to Auto Attendant or another Trunk.
IP \ Value
0
1
2
3
4
5
6
7
8
9
Unit
05-01-04
0
2
4
6
8
15
30
60
120
254
sec.
Note:
0 = Incoming trunk immediately connects to Auto Attendant or another trunk without ringing assigned stations.
1-9 =Incoming trunk connects to Auto Attendant or another trunk after 2-254 seconds ringing.
Also see Program 05-11-04 for Night delay and Program 05-17-4 for Lunch delay.
05. Busy Remind Cycle Time (Off-Hook Ringing)
This parameter sets the timer an incoming trunk periodically rings a busy station. It is used to remind the busy station
that another trunk is waiting on the line. A muted, one-second ring will be given to the station through the speaker to
indicate the waiting call. The ring will be repeated at intervals defined by this busy remind cycle time.
This parameter also sets the timing for the SLT Camp-On feature (see Mode 05-08-03 SLT Camp On Time) and the
camp on tone for key stations.
IP \ Value
0
1
2
3
4
5
6
7
8
9
Unit
05-01-05
0
2
4
6
8
15
30
60
120
254
sec.
06. Pause Time
This parameter sets the system pause time duration for speed dial entry, trunk access time and voice mail call
forwarding tone delay.
IP \ Value
0
1
2
3
4
5
6
7
8
9
Unit
05-01-06
400
600
800
1000 1200 1400 1600 1800 2000 2200
ms.
07. DTMF Generation Time
This parameter sets DTMF generation time. It may need to be lengthened to access some Voice Mail or answering
machines.
IP \ Value
0
1
2
3
4
5
6
7
8
9
Unit
05-01-07
48
64
80
100
114
132
156
164
180
196
ms.
08. Call Forward No Answer Transfer Time
This parameter sets the amount of time a call is ringing a station (set Call Forward No Answer) before it is transferred
to another station.
IP \ Value
0
1
2
3
4
5
6
7
8
9
Unit
05-01-08
10
20
30
40
50
60
70
80
90
100
ms.
Содержание G1E Plus
Страница 1: ...G1E Hybrid IP Telephone System Programming Manual Rev 2 2d ...
Страница 15: ...DK6 Key Telephone Key Layout 36 Button DK6 Key Telephone Key Layout 18 Button ...
Страница 48: ...03 Reserved 04 Reserved 05 Reserved 06 Reserved 07 Reserved 08 Reserved ...
Страница 113: ......
Страница 126: ...Program 93 Not Used in North America ...
Страница 131: ...35 trk 01 Trunk Type PABX CO 35 trk 02 Trunk Signalling Type dial pulse DTMF ...