background image

This product features blood pressure measurement, pulse rate measurement

and the result storage. The design provides you with two years of reliable 

service.  

Readings taken by this blood pressure monitor TMB-1491-BHJ is equivalent to

those obtained by a trained observer using the cuff and stethoscope

ausculta�on method.  

This manual contains important safety and care informa�on, and provides

step by step instruc�ons for using this blood pressure monitor. Read the 

manual thoroughly before using this product.

Features:

 

Maximum storage of 60 records per user

General Description

Up-to-date measuring-during-infla�on technology

60 mm × 40.5 mm Digital LCD display

Indications for Use

This Blood Pressure Monitor TMB-2080 is a digital monitor intended for use in 

measuring blood pressure and heartbeat rate with arm circumference ranging from

22 cm to 32 cm (about 8¾˝-12½˝), 22 cm to 42 cm (about 8¾˝-16½˝).

It is intended for indoor, adult use only.

Measurement Principle

 

1. The device is not suitable for use on the women who are or may be pregnant.

2. The device is not suitable for use on pa�ents with implanted, electrical devices, 

    such as cardiac pacemakers, defibrillators.

Contraindications

This product uses the Oscillometric Measuring method to detect blood pressure. 

Before every measurement, the unit establishes a “zero pressure” equivalent to the 

atmospheric pressure. Then it starts infla�ng the arm cuff, meanwhile, the unit 

detects pressure oscilla�ons generated by beat-to-beat pulsa�le, which is used to 

determine the systolic and diastolic pressure, and also pulse rate. 

Safety Information

The signs below might be in the user manual, labeling or other component. They 

are the requirement of standard and using.

Symbol for “THE OPERATION 

GUIDE MUST BE READ”

Symbol for “MANUFACTURER”

Symbol for “SERIAL NUMBER”

Symbol for “TYPE BF APPLIED 

PARTS”

Symbol for “DIRECT CURRENT”

Symbol for “ENVIRONMENT 

PROTECTION - Electrical waste 

products should not be 

disposed of with household 

waste. Please recycle where 

facili�es exist. Check with your 

local authority or retailer for 

recycling advice”

Symbol for “MANUFACTURE 

DATE”

For indoor use only

F1

T1A/250V Φ3.6*10CCC

Symbol for “Class II Equipment”

SN

Symbol for “Recycle”

INTRODUCTION

INTRODUCTION

2

3

Indicates the need for the user 

to consult the instruc�ons for 

use for important cau�onary 

informa�on such as warnings 

and precau�ons that cannot, 

for a variety of reasons , be 

presented on the medical 

device itself.

Содержание TMB-1491-BHJ

Страница 1: ...onitor Please read the user manual carefully and thoroughly so as to ensure the safe usage of this product Keep this manual for further reference in case any issues arise Version 1 0 Guangdong Transte...

Страница 2: ...the Records Delete the Records INFORMATION FOR USER 21 Tips for measurement Maintenance ABOUT BLOOD PRESSURE 23 What are systolic pressure and diastolic pressure What is the standard blood pressure c...

Страница 3: ...such as cardiac pacemakers de brillators Contraindications This product uses the Oscillometric Measuring method to detect blood pressure Before every measurement the unit establishes a zero pressure...

Страница 4: ...f patient blood circulation When measurement please avoid compression or restriction of the connection tubing CAUTION The device cannot be used with HF surgical equipment at the same time The ACCOMPAN...

Страница 5: ...equipment to cool from the maximum storage temperature between uses until it is ready for intended use This equipment needs to be installed and put into service in accordance with the information prov...

Страница 6: ...the measurement 6V 1A Do not use new and used ba eries together Do not use di erent types of ba eries together Do not dispose the ba eries in re Ba eries may explode or leak Remove ba eries if the dev...

Страница 7: ...EM bu on will increase the number by one in a cycling manner When you get the right year press SET bu on to con rm the entry The screen will then show a blinking number represen ng the MONTH It is imp...

Страница 8: ...between user 1 user 2 and USER G guest 1 Press SET bu on to ensure your choice it will show User ID and donE and then turn o 2 7 A er the UNIT is set the LCD will display donE rst then display all th...

Страница 9: ...ment Sensi ve people including pregnant women pre eclamp c and those who implanted medical electronic instruments should avoid using the unit whenever possible Keep the monitor at least 20 cen meters...

Страница 10: ...eep breaths Rest for 5 minutes before rst measuring Wait at least 3 minutes between measurements This allows your blood circula on to recover The pa ent must relax as much as possible and do not move...

Страница 11: ...1 is shown rst Each new measurement is assigned to the rst 1 record All other records are pushed back one digit e g 2 becomes 3 and so on and the last record 60 is dropped from the list 2 Each press M...

Страница 12: ...can delete all results for the selected user by following steps Take User 1 for example If there is no record when you press MEM bu on to check the record the right display will be shown 3 Tips for Me...

Страница 13: ...n indicates that a pulse irregularity consistent with an irregular heart beat was detected during measurement Usually this is NOT a cause for concern However if the symbol appears o en we recommend yo...

Страница 14: ...during use please check the following points PROBLEM SYMPTOM CHECK THIS REMEDY No power Low batteries Error message Display will not light up Ba eries are exhausted Replace with new ba eries Insert th...

Страница 15: ...ery Powered Mode Internally Powered ME Equipment AC Adapter Powered Mode Class II ME Equipment A temperature range of 5 C to 40 C A rela ve humidity range of 15 to 90 non condensing but not requiring...

Страница 16: ...ses Bio compatibility ISO 10993 1 2018 Biological evaluation of medical devices Part 1 Evaluation and testing within a risk management process ISO 10993 5 2009 Biological evaluation of medical devices...

Страница 17: ...anufacturer s declaration electromagnetic emissions RF emissions CISPR 11 RF emissions CISPR 11 Group 1 Class B Class A Comply Compliance Harmonic emissions IEC 61000 3 2 Voltage fluctuations flicker...

Страница 18: ...3 Test specifications for ENCLOSURE PORT IMMUNITY to RF wireless communicati ons equipment Band MHz Modulation W Distance m IMMUNITY TEST LEVEL V m TETRA 400 Pulse modulation b 18 Hz GMRS 460 FRS 460...

Отзывы: